background image

8.0  Labels

The labels must be present and legible.

MANC33 Rev B

020320

11

REV

TITLE

ITEM NO.

SIZE

SHEET

SCALE

412-05069

Label, Post Anchor, Various Info, 

Warning, Inspection Grid             

REVISIONS

REV

DRAWN

DATE

P1 PRELIMINARY INITIAL RELEASE

DESCRIPTION

10-3-19

Sam

A PRELIMINARY INITIAL RELEASE

10-14-19

Sam

THE INFORMATION EMBODIED IN THIS DOCUMENT IS STRICTLY 

CONFIDENTIAL AND ARE SUPPLIED WITH THE UNDERSTANDING 

THAT THEY WILL NOT BE DISCLOSED TO THIRD PARTIES

1:1

1/1

A

A

GENERAL NOTES:

1.

2.

3.

4.

WEIGHT (FOR REFERENCE ONLY)

N/A

N/A

ZW

Samuel Andrade

N/A

N/A

N/A

Polycarbonate coated vinyl 

APPLICABLE STANDARDS:

ASME Y14.5-2009 & DIN ISO 2768

EXCEPTION: TRAILING ZEROS DENOTE 

TOLERANCE
UNLESS OTHERWISE SPECIFIED DIMENSIONS 

ARE IN MILLIMETERS (mm)

TOLERANCES ARE:

0 to 6 ...........................................

6 to 30 .........................................

30 to 120 .....................................

120 + ...........................................

ANGLES .....................................

APPROVED

MFG

CHECKED

SURFACE ROUGHNESS

SURFACE FINISH

10-3-19

MATERIAL

DRAWN

10-14-19

N/A

N/A

0.1

0.2

0.3

0.5

0.5

PANTONE black C

PANTONE 152C

PANTONE 5415C

152mm

76mm

40mm

DIE CUT LINES

DO NOT REMOVE 

LABEL

All Manufacturer’s instructions, labels, and warnings must be read 

before use and followed at all times for proper use, maintenance, 

and inspection. Users must be fully trained and knowledgeable 

about all government and regulatory requirements applicable to 

workplace safety. This equipment must be installed and used under

the supervision of a qualified person. Failure to follow instructions 

or misuse of this product may result in serious injury or death. 

Exercise caution using this equipment near hazardous thermal, 

electrical, or chemical sources. Avoid contact with sharp edges, 

abrasive surfaces, chemicals, salt water, acids, and alkalines. See 

instructions for loading direction diagram and restrictions on use 

with components, subsystems, or systems with which this product 

is designed to be used. Inspect the system before each use, 

following guidelines found in the user instruction manual supplied 

with product at time of shipment. Do not use system if unsafe 

conditions are present. Remove from service if equipment is 

subjected to fall arrest forces. Always log inspection results in 

user manual and on inspection grid label. 

412-05069 Rev A

Model#:

Date of Mfr: 

Serial #:  

MARK ON DATE GRID A) INITIAL SERVICE DATE

B) DATE OF PASSED INSPECTION . IF UNIT FAILS INSPECTION 

REMOVE IT FROM SERVICE 

YEAR

Material: Steel

Meets: ANSI Z359.18-2017 Type D for Steel and Concrete

Meets: OSHA 1926.502 for Wood, Steel, and Concrete

Minimun Service Temperature: +10 F

Minimum Breaking Strength (MBS): 5,000 lbs. 

800-719-4619      falltech.com

DO NOT REMOVE 

LABEL

All Manufacturer’s instructions, labels, and warnings must be read 

before use and followed at all times for proper use, maintenance, 

and inspection. Users must be fully trained and knowledgeable 

about all government and regulatory requirements applicable to 

workplace safety. This equipment must be installed and used under

the supervision of a qualified person. Failure to follow instructions 

or misuse of this product may result in serious injury or death. 

Exercise caution using this equipment near hazardous thermal, 

electrical, or chemical sources. Avoid contact with sharp edges, 

abrasive surfaces, chemicals, salt water, acids, and alkalines. See 

instructions for loading direction diagram and restrictions on use 

with components, subsystems, or systems with which this product 

is designed to be used. Inspect the system before each use, 

following guidelines found in the user instruction manual supplied 

with product at time of shipment. Do not use system if unsafe 

conditions are present. Remove from service if equipment is 

subjected to fall arrest forces. Always log inspection results in 

user manual and on inspection grid label. 

412-05069 Rev A

Model#:

Date of Mfr: 

Serial #:  

MARK ON DATE GRID A) INITIAL SERVICE DATE

B) DATE OF PASSED INSPECTION . IF UNIT FAILS INSPECTION 

REMOVE IT FROM SERVICE 

YEAR

Material: Steel

Meets: ANSI Z359.18-2017 Type D for Steel and Concrete

Meets: OSHA 1926.502 for Wood, Steel, and Concrete

Minimun Service Temperature: +10 F

Minimum Breaking Strength (MBS): 5,000 lbs. 

800-719-4619      falltech.com

10mm

CUT OUT

Содержание 78012CSSD

Страница 1: ...221 USA Tel 800 719 4619 Fax 323 752 5613 This manual is intended to meet the Manufacturer s Instructions as required by the American National Standards Institute ANSI Z359 and should be used as part...

Страница 2: ...6 0 Maintenance Service and Storage 7 0 Inspection 8 0 Labels 9 0 Definitions Appendix A 3 4 4 5 6 9 9 11 12 14 MANC33 Rev B 020320 2 For purposes of this manual the FallTech Post Anchors in all itera...

Страница 3: ...eased fall arrest forces placed on the user s body In addition the onset of suspension trauma after a fall even may be accelerated for heavy users The user of the equipment discussed in this manual mu...

Страница 4: ...nchors used as the anchorage component of a PFAS to protect the user in the event of a fall PFAS typically consists of an anchorage a Full Body Harness FBH and a deceleration device such as a Energy A...

Страница 5: ...to a object in a manner whereby the gate of the snap hook or carabiner would be prevented from fully closing and locking Always guard against false connections by visually inspecting for closure and...

Страница 6: ...er moves laterally out from under the anchor and creates an expanded work zone condition If a fall event occurs the worker would swing back toward the anchorage The swinging action generates considera...

Страница 7: ...2 Hex Nuts Install a minimum of 4 threaded rods as shown on Figure 5 Torque evenly to 35 ft lbs Figure 5 I Beam Installation Top View Front View Isometric View 5 7 Weld On Installation FallTech requi...

Страница 8: ...for wood deck 1 Measure and cut four 2 x 6 Support Blocks and fasten as shown in Figure 7 Figure 7 Wood Roof Installation Support Blocks 2 x 6 Support Blocks 9 3 4 Below Surface 22 5 max 22 5 max 2 Me...

Страница 9: ...ight Use Rescue and confined space factory maintenance Good storage conditions indoor or infre quent outdoor use room temperature clean environments Before each use Annually Moderate to Heavy Use Tran...

Страница 10: ...________ Date of Manufacture _________________________ INSPECTION DATE INSPECTOR COMMENTS PASS FAIL CORRECTIVE ACTION NEEDED APPROVED BY 7 4 Inspection Document Record inspection results on the Inspec...

Страница 11: ...esigned to be used Inspect the system before each use following guidelines found in the user instruction manual supplied with product at time of shipment Do not use system if unsafe conditions are pre...

Страница 12: ...fall protection program who through training and knowledge is capable of identifying evaluating and addressing existing and potential fall hazards and who has the employer s authority to take prompt c...

Страница 13: ...sitioning The act of supporting the body with a positioning system for the purpose of working with hands free Positioning Lanyard A lanyard used to transfer forces from a body support to an anchorage...

Страница 14: ...h OSHA only 78012CSSC 12 Post Anchor SRL Cradle 12 x 12 Base Concrete Steel 78012CSWE 12 Post Anchor Welded Eye 12 x 12 Base Concrete Steel 78012CSTH 12 Post Anchor 5 8 11 Threaded Hole 12 x 12 Base C...

Страница 15: ...h OSHA only 78218CSSC 18 Post Anchor SRL Cradle 12 x 12 Base Concrete Steel 78218CSWE 18 Post Anchor Welded Eye 12 x 12 Base Concrete Steel 78218CSTH 18 Post Anchor 5 8 11 Threaded Hole 12 x 12 Base C...

Страница 16: ...A only 78316P 16 x 16 Plate 7840SC SRL Cradle for Post Anchor 5 000 lbs Min Zinc Plated Steel 7840SD Swivel D Ring for Post Anchor Table 1B Post Anchor Compliance Chart Part Numbers Application ANSI Z...

Страница 17: ...S MUST BE REMOVED 1 WEIGHT FOR REFERENCE ONLY N A N A N A RAYMOND HAN 15 03 LBS N A HOT DIP GALVANIZED AFTER WELDING IF WELDING APPLIES MIN COATING GRADE 75 PER ASTM A123 STEEL Q235 OR APPROVED EQUIVA...

Отзывы: