 SMP Series - Overview

T

he FALCON

®

SUP Series UPS has the unique ability to operate from either

120Vac domestic or 230Vac international utility power, while providing
120Vac domestic output power. The SUP does not perform frequency 
conversion, however it is the ideal solution for the international traveller
requring voltage conversion.   

The Line-interactive or Automatic Voltage Regulator (AVR) feature provides
output voltage regulation, while the UPS is operating from the utility power.
This keeps the connected equipment's operating voltage within reasonable
limits during abnormal utility power conditions such as brown-outs, high line
voltages and surges. 

All SUP models are microprocessor controlled. A Liquid Crystal Display
(LCD) is conveniently located on the front panel. This display gives 
immediate and detailed UPS and power information without having to 
connect an expensive monitoring computer. An intelligent RS-232 computer
interface port is also located on the UPS rear panel in the event remote 
monitoring or unattended computer shutdown is required. An optional 
external SNMP/HTTP agent is available, giving the ability to manage the
UPS remotely across a LAN, WAN or via the Internet.

Unlike many other line-interactive UPSs on the market, the SUP models 
produce a sinewave output voltage, just like the incoming utility power. This
assures your delicate electronic equipment will always receive the sinewave
power it was designed for. 

All models have an advanced two-stage battery charger providing safe, fast
battery recharging while yielding a longer battery life.

All models have advanced surge protection circuitry to prevent damaging
power line transients from reaching your equipment. Additional surge protect-
ed, RJ11 telephone jacks are provided on the UPS rear panel. 

3

Содержание SUP1.0K-1C

Страница 1: ...INC SUP SeriesTM User s Guide 700 1000VA WWW FALCONUPS COM 800 842 6940 SUP700 1C SUP1 0K 1C FALCON ELECTRIC INC Irwindale CA 91706 Tel 626 962 7770 Fax 626 962 7720 OM48031 SUP 01 09 04 Rev A 5116 Az...

Страница 2: ...Diagram Description 9 Chapter 4 Operation 11 Turning The UPS On and Off 11 UPS Self Test 11 UPS Overload Condition 11 DC Start Cold Start 11 Green Mode Function 11 Battery Charging 12 UPS Reset 12 Re...

Страница 3: ...detergent on the UPS Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servicing of batteries should be performed or supervised by personnel kno...

Страница 4: ...isplay gives immediate and detailed UPS and power information without having to connect an expensive monitoring computer An intelligent RS 232 computer interface port is also located on the UPS rear p...

Страница 5: ...50Hz European source verify the connected equipment was designed to operate from a 120Vac 50Hz power source This information is stated on the nameplate label located on the model number label located...

Страница 6: ...nd will open when the utility fails Pins 5 and 4 are normally open and will close at the low battery indication The UPS will shut down when a 5 12 Vdc voltage is applied across Pins 6 and 7 for three...

Страница 7: ...quid Crystal Display LCD is provided Please reference the number designation for the display function and the function descriptions referenced in this manual Refer to pages 6 8 in this manual C Two LC...

Страница 8: ...ode The sinewave symbol will be displayed when the UPS is operating normally from the utility line Battery Mode The sinewave and battery symbols will blink when the UPS is operating on its internal ba...

Страница 9: ...0 C the UPS will shutdown to prevent damage due to excessive overheating 9 Fan off This symbol is used on special extended backup models only 10 Alarm off The audible alarm has been silenced To reset...

Страница 10: ...ill turn on when the display reaches zero Battery Minutes to off The estimated remaining battery run time while in battery backup mode LCD Metering Display Modes use display scroll buttons to change m...

Страница 11: ...t the incoming telephone line to one of the jacks Then connect the fax modem or other device to be protected to the other jack 7 Audible Alarms Reference the following table ALARM PERIOD STATUS INDICA...

Страница 12: ...if the overload is removed the UPS will automatically turn on again If the overload is still present the UPS will turn off and stay off requiring the UPS be manually restarted Always correct any over...

Страница 13: ...to a loss of utility power 7 UPS Reset In the event the UPS will not accept commands and appears to be locked up depress the control button for and hold for ten seconds The UPS CPU will be reset 8 Re...

Страница 14: ...r computer room environments the batteries should be replaced every three to five years Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servic...

Страница 15: ...er s instructions may cause interference to radio and television reception All models covered in this manual have been tested and found to comply with the limits for a Class A computing device in acco...

Страница 16: ...rds The RMA number issued must appear on the outside of the shipping carton The original shipping container must be used when returning any SUP Series product Falcon Electric will not assume any respo...

Страница 17: ...ng the nature of the trouble experienced and the disposition of the equipment after repair The equipment will be returned freight collect by FALCON to the location specified via the best and least exp...

Страница 18: ...dity 10 to 95 Non Condensing Cooling Low Velocity Forced Air Fans Audible Noise 1 meter 45dBA Controls and Indicators Control One Main Control Button UPS On Off Self Test Reset Silence Alarms Selectio...

Отзывы: