background image

SG UPS Features.

.

.

.

.

.

.

1

SG Series Online UPS Block Diagram.

.

.

.

.

1

Important Safety Instructions (READ FIRST) .

.

.

.

2

Chapter 1. 

SG Series UPS Overview

.

.

.

.

.

3

True Regenerative Online Design

.

.

.

.

3

Input Power Factor Correction

.

.

.

.

3

Microprocessor Control

.

.

.

.

.

3

SNMP/HTTP Remote Management

.

.

.

.

3

Extended Battery Bank Option

.

.

.

.

4

Frequency Converter Option .

.

.

.

.

4

Chapter 2.

Installation Instructions

.

.

.

.

.

5

Dip Switch Settings DIagrams 

.

.

.

.

7

Extended Battery Bank Interconnection

.

.

.

.

8

Extended Battery Bank Installation Procedure

.

.

8

Extended Battery Bank Selection Guide

.

.

.

9

Chapter 3. 

Operation

.

.

.

.

.

.

.

10

Front Panel Indicators & Function Key Diagram

.

.

10

Front Panel Function Description

.

.

.

.

10

Audible Alarms

.

.

.

.

.

.

12

Category One Alarms .

.

.

.

.

12

Category Two Alarms .

.

.

.

.

12

Chapter 4. 

Rear Panel Details

.

.

.

.

.

.

13

SG2K-X1T & SG3K-X1T Rear Panel.

.

.

13

SG2K-X2T & SG3K-X2T Rear Panel 

.

.

.

13

Chapter 5. 

Communications Interfaces.

.

.

.

.

14

RS-232 Interface (DB-9)

.

.

.

.

.

14

Communications Option Slot .

.

.

.

.

14

Contact Closure & Opto Interface Options

.

.

.

15

Chapter 6. 

Maintenance & Technical Support

.

.

.

.

18

Care & Maintenance

.

.

.

.

.

.

18

Battery Life vs. Temperature .

.

.

.

.

18

Battery Replacement .

.

.

.

.

.

18

Storing the UPS and Batteries.

.

.

.

.

19

FCC Considerations

.

.

.

.

.

.

19

Technical Support & RMA Procedure .

.

.

.

20

Requesting Technical Information or Support.

.

.

20

FALCON Web Support .

.

.

.

.

.

20

Warranty

.

.

.

.

.

.

.

.

21

Specifications .

.

.

.

.

.

.

.

22

TABLE OF CONTENTS

Содержание SG2K-X1T

Страница 1: ...ic Inc All rights reserved All other brand names and trademarks are the property of their respective owners The information stated in this document is subject to change without notice 2006 02 24 Falco...

Страница 2: ...3 Operation 10 Front Panel Indicators Function Key Diagram 10 Front Panel Function Description 10 Audible Alarms 12 Category One Alarms 12 Category Two Alarms 12 Chapter 4 Rear Panel Details 13 SG2K X...

Страница 3: ...On Line Design Input Power Factor Correction Wide Input Voltage Window Pure Sinewave Output Precision Output Voltage Regulation Superior Brownout Surge and Transient Protection Internal System Bypass...

Страница 4: ...r supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing the UPS batteries use the same number and type of batte...

Страница 5: ...s feature provides the following benefits Breaks neutral to ground current and noise paths Greatly reduces common mode noise Gives a superior level of protection against high frequency noise and trans...

Страница 6: ...ter recharging Please specify your extended battery and charger requirements at the time of your initial order Frequency Converter Option With a factory modification at the time of order any SG Series...

Страница 7: ...own or to the enabled position the Green Mode function is activated When the load connected to the output of the UPS drops to under 10 of the full rated UPS output for 30 seconds the UPS is automatica...

Страница 8: ...T BE INSTALLED IN AN ENCLOSED AREA 11 Plug the UPS power cord into the nearest grounded wall outlet 12 Turn the input circuit breaker located on the UPS rear panel to the on position The internal UPS...

Страница 9: ...default Up Up 115V SW2 SW1 VOLTAGE Down Down 220V Down Up 230V Factory Default Up Down 240V Up Up 200V SW3 FUNCTION Down GREEN MODE ON Up GREEN MODE OFF SWITCH SETTINGS FOR 1 MODELS SWITCH SETTINGS FO...

Страница 10: ...m the following a Verify the battery charger circuit breaker is in the off down position b On the battery bank nameplate label located on the rear panel verify the battery charger input voltage matche...

Страница 11: ...5Vdc 4A 82 5Vdc 4A 82 5Vdc 4A 82 5Vdc 4A OF CHARGERS 1 1 1 1 2 3 FOR 2KVA MODELS BATTERY OPTION MODELS W O Charger SGB2S7 3K3 SGB2S7 3K3 SGB5S7 3K6 SGB2S7 3K3 SGB5S7 3K6 SGB5S7 3K6 BATTERIES 16 Pieces...

Страница 12: ...Second LED is let when the battery level is above the low battery warning Level The first LED is lit when the battery level is above the battery cutoff voltage 3 LINE SITE WIRING FAULT INDICATOR LED F...

Страница 13: ...he following describes the different modes of operation for this button a Depressing this button when the UPS is off and the utility voltage is not present or with the UPS input circuit breaker in the...

Страница 14: ...TEST BUTTON DEPRESSED 2 Category two alarms a Three short beeps indicate the SG UPS output voltage is out of proper operating range SG UPS OUTPUT VOLTAGE IS OUT OF PROPER RANGE b Four short beeps indi...

Страница 15: ...her Configurations COVER PLATE FOR OPTIONAL SNMP AGENT DIP SWITCHES RS 232 CONNECTOR COOLING FANS DO NO BLOCK MAIN POWER SWITCH INPUT CIRCUIT BREAKER LINE CORD INLET OUTPUT FUSES 2 places OPUTPUT RECE...

Страница 16: ...the green cable supplied with the UPS There are communications options that WILL DISABLE the RS 232 port and render it inoperable The options are as follows a Internal SNMP HTTP agent option installe...

Страница 17: ...ommons JP3 open Alarm common only PIN JUMPER ASSIGNMENT FOR THE FALCON UA88374 RELAY OPTION BOARD no on bypass signal PIN JUMPER ASSIGNMENT FOR THE FALCON UA88376 RELAY OPTION BOARD with on bypass sig...

Страница 18: ...upon utility loss 4 Common for pins 2 3 5 5 Low Battery N O Closes at low battery 6 Remote Shutdown Applying a 5 12Vdc voltage level for 500ms while the UPS is on battery will shutdown the UPS 7 Not U...

Страница 19: ...Shutdown on battery operation only 2 Remote Shutdown Common 3 Not Used 4 Low Battery Common 5 Low Battery N O 6 Not Used 7 Not Used 8 Utility Fail 10Vdc 9 Utility Fail 10Vdc PIN JUMPER ASSIGNMENT FOR...

Страница 20: ...Falcon Service Department see page 20 for contact information Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servicing of batteries should b...

Страница 21: ...l interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the inst...

Страница 22: ...eturning any SG Series product Falcon Electric will not assume any responsibility for shipping damage In the event of shipping damage you will be notified of the damage and be instructed to file a cla...

Страница 23: ...NY IMPLIED WARRANTY OF MERCHANTABILITY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND EXPRESS WARRANTIES THAT THIS PRODUCT WILL CONFORM TO ANY AFFIRMATION OR PROMISE FOR THIS PRODUCT AND THE...

Страница 24: ...se 4ms After Overload Auto Transfer to UPS Electrical Connections Input 6 Cord with 5 20P Detachable 6 Line Cord with a L6 20P or Schuko 6 Cord wit L5 30P Detachable 6 line cord with a L6 20P or Schuk...

Отзывы: