Figure 1 - Front View

SECTION 1 - SITING

All PRO-LITE models have been designed in a modular

form which consists of base, counter and free-standing

units.
Information which relates to individual models is listed in

Table 1.
Free-standing and base models should be installed

upon a firm, level surface and adjustable feet are

provided for levelling purposes.
Counter units must be positioned upon a table, counter

or similar surface.
Vertical and horizontal clearances required from the top

and sides of a particular unit to any overlying

combustible surface (ie wall, partition, etc) are listed in

Table 1. Relevant fire regulations must be complied

with.

Mounting Counter Units on the Oven
When mounting a counter unit upon a PRO-LITE oven,

it is recommended that units which carry liquids,

i.e. fryers and bain marie, are secured as follows:
Remove oven outer back panel.
Remove oven crown plate.
Position unit(s) which require to be secured upon oven.
Secure hob unit(s) to oven through side flange centre

holes into the threaded inserts in the base(s) of hob

unit(s). Use fixings provided (packed separately) and

replace oven back panel.
The unit is now ready for electrical connection.

Mounting Counter Units upon a Hotcupboard
PRO-LITE hotcupboards are designed to be used in

conjunction with counter models. Assembly is achieved

by means of two shouldered fixings being applied to the

underside of a top unit from inside a base appliance as

detailed in Figure 1.

SECTION 2 - ELECTRICAL SUPPLY

AND CONNECTION

Electrical ratings are as stated on the unit data

plate. The listing in Table 1 is based on standard UK

specification at 230V

~

.

Wiring must be executed in accordance with the

regulations listed in this booklet.
WARNING: Each individual appliance must be

earthed!
After completion of installation, the method of operation

should be demonstrated to the kitchen staff.

The isolating switch location, for use in an emergency

or during cleaning should also be pointed out.

LD32, LD33, LD35, LD36, LD38 and LD39

DRY BAINS MARIE
LD34, LD37 and LD43 WET BAINS MARIE
These models are designed to be connected to a single

phase ACsupply using the 2 metre mains lead fitted as

standard.
Wires are coloured in accordance with the following

code and should be connected to the plug as follows:
EARTH to terminal marked E

or coloured GREEN or GREEN/YELLOW.
NEUTRAL to terminal marked N or coloured BLACK.
LIVE to terminal marked L or coloured RED.
Units which receive power from a plug, adaptor or

distribution board must be individually protected by a

fuse with an appropriate rating. (See Table 1)
For models with two mains leads, each lead requires to

be protected by a fuse with an appropriate rating.

(See Table 1)
Any replacement supply cable must be 1.5mm

2

, cord

code designation 245 IEC57 (CENELECH05 RN-F).
For internal connection, outer sheathing must be

stripped 140mm from the cable end. The live and

neutral conductors must be trimmed so that Earth

conductor is longer by 50mm. Pass inlet cable through

the rear panel cord grip and ensure that cable is routed

without leaving excessive free length inside unit.

SECTION 3 -

USING AND CLEANING PRO-LITE UNITS

IMPORTANT: GENERAL NOTES ON CLEANING
Disconnect unit from electricity supply prior to

cleaning
Never use a coarse abrasive to clean exterior

panels. A soft cloth with a warm water and

detergent solution is sufficient.
Never attempt to steam clean a unit or hose it down

with a jet of water.

LD32, LD33, LD35, LD36, LD38 and LD39

DRY BAINS MARIE
LD34, LD37 and LD43 WET BAINS MARIE

The LD32, LD33, LD34,

LD35, LD36 and LD37 are

supplied with 4.5 litre pots.
The LD38, LD39 and

LD43 models accomodate

a mix of gastronorm

containers and bridging

bars are provided as

standard. Containers are

not supplied.
The LD39 and LD43

models are designed to

hold 1/4, 1/2 and 1/1 size

gastronorm trays.