Technical Installation & Information Table 
 

Model 

Width 

Depth 

Height 

Weight   Rating 

Fuse Rating 

LD33 Dry Bains Marie 

300mm 

630mm 

285mm 

15kg 

0.48kW 

3 amp 

LD34 Wet Bains Marie 

300mm 

630mm 

285mm 

15kg 

1.0kW 

5 amp 

LD36 Dry Bains Marie 

450mm 

630mm 

285mm 

18kg 

0.75kW 

5 amp 

LD37 Wet Bains Marie 

450mm 

630mm 

285mm 

18kg 

1.0kW 

5 amp 

LD38 Dry Bains Marie 

300mm 

630mm 

285mm 

15kg 

0.48kW 

3 amp 

LD39 Dry Bains Marie 

600mm 

630mm 

285mm 

22kg 

0.75kW 

5 amp 

LD43 Wet Bains Marie 

600mm 

630mm 

285mm 

22kg 

2.0kW 

13 amp 

 
 

SECTION 1 – SITING 
 

All PRO-LITE models have been designed in a modular form which consists of base, counter and free-
standing units. 
Information which relates to individual models is listed in Table 1. 
Free-standing and base models should be installed upon a firm, level surface and adjustable feet are 
provided for levelling purposes. 
Counter units must be positioned upon a table, counter or similar surface. 
Vertical and horizontal clearances required from the top and sides of a particular unit to any overlying 
combustible surface (ie wall, partition, etc) are listed in Table 1. Relevant fire regulations must be complied 
with. 
 
Mounting Counter Units on the Oven 
 
When mounting a counter unit upon a PRO-LITE oven, it is recommended that units which carry liquids, i.e. 
fryers and bain marie, are secured as follows: 
Remove oven outer back panel. 
Remove oven crown plate. 
Position unit(s) which require to be secured upon oven. 
Secure hob unit(s) to oven through side flange centre holes into the threaded inserts in the base(s) of hob 
unit(s). Use fixings provided (packed separately) and replace oven back panel. 
The unit is now ready for electrical connection. 
 
Mounting Counter Units upon a Hotcupboard 
 
PRO-LITE hotcupboards are designed to be used in conjunction with counter models. Assembly is 
achieved by means of two shouldered fixings being applied to the underside of a top unit from inside a base 
appliance as detailed in Figure 1. 
 
 
 
 
 
 

 

 Figure 1 Front view     

 
 
 
 
 
SECTION 2 - ELECTRICAL SUPPLY AND CONNECTION 
 
Electrical ratings are as stated on the unit data plate. The listing in Table 1 is based on standard UK 
specification at 230V. 
Wiring must be executed in accordance with the  regulations listed in this booklet.  
 
WARNING: Each individual appliance must be earthed! 
 