Falcon OM48021-1 Скачать руководство пользователя страница 7

OM48021-1 Rev. C 

7

 
 

Audiable Alarms 

Audible alarm signals are divided into two catagories.  Each category represents a different level of alarm status. 
Catagory One Alarms represent normal or correctable operational alarms. Category Two Alarms are sounded in 
the event of abnormal operation  This will provide the end-user a more detailed notification of the SVR’s status. 

 
1. 

Category One Alarms:  

 
 

• One long beep prior to a short beep, lets the user know the SVR is in an OVER LOAD, OVER CREST,  

      or FAULT situation. 
 
   

 

     

──

 

  =  SVR IS IN OVERLOAD OR OVER CREST  

 

      

   • When ON/OFF button pressed, the associated actions will be initiated and there will be one short  

 

      beep. 

 
 

   

 

  

  = WHEN SVR FRONT PANEL BUTTON DEPRESSED 

     
   • When the INITIAL SELF-TEST has been completed, there will be one short beep. 
 
   

 

  

  = WHEN SVR FRONT PANEL BUTTON DEPRESSED 

 
2. 

Category Two Alarms: 

 
    

 • Three short beeps: indicates the SVR output voltage is out of proper operating range. 

 
 

                              

 

 

  = SVR OUTPUT VOLTAGE OUT OF PROPER RANGE. 

 
 

 • Four short beeps: indicates the SVR output frequency is out of proper operating range. 

 
 

                             

 

 

 

  =  SVR OUTPUT FREQUENCY OUT OF PROPER RANGE. 

 
 

 • Five short beeps: indicates the SVR is in an

 

over-temperature condition. 

 
 

                             

 

 

 

 

  = SVR INTERNAL TEMPERATURE TOO HIGH 

 
3.  If the INITIAL SELF-TEST cannot be completed after start-up, the SVR will sound the following alarms upon the 

stated conditions: 

 

•     Continuous rapid beeping for about 5 seconds and the SVR shuts down - 

Output voltage over range

 
 

 

 

 

 

 

 

  

 

 

 

 

  

 

 

 

 

  

 

 

 

 

  

 

 

 

 

   = 

Output voltage over range

 

• 

Continuous rapid beeping for about 2 seconds and the SVR shuts down - 

The SVR performed a DC start, but 

there is no output frequency set in memory. 

 
 

 

 

 

 

 

  

 

 

 

 

   = 

The SVR performed a DC start, but there is no output frequency set in memory. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание OM48021-1

Страница 1: ...nia 91706 800 842 6940 Fax 626 962 7720 Email sales falconups com 2005 Falcon Electric Inc All rights reserved All other brand names and trademarks are the property of their respective owners The information and specifications stated in this document are subject to change without notice 2005 03 21 Falcon Falcon Electric and UPS Plus logos are registered trademarks of Falcon Electric Inc FALCON ELE...

Страница 2: ...S FEATURES COMPACT SIZE LIGHT WEIGHT WIDE INPUT VOLTAGE WINDOW TIGHT OUTPUT VOLTAGE REGULATION 2 INPUT POWER FACTOR CORRECTION SURGE PROTECTION HIGH EFFICIENCY OVER CREST RATIO LED INDICATOR RS 232 INTERFACE SYSTEM BLOCK DIAGRAM ...

Страница 3: ... indoor area free of conductive contaniments The system is lightweight and can be easily moved Some important points to consider when positioning a unit for operation It is preferable that a dedicated outlet is accessible to connect the SVR DO NOT modify the supplied cord in any way nor should an extension cord of any kind be used The cord paths in the system installation should remain clear of fo...

Страница 4: ... as setting dip switch settings also located on the SVR rear panel 3 For the 1kVA model connect the power cord to the inlet located on the SVR rear panel 4 Select a suitable location for the SVR near enough to the computer or equipment to connect the power cord Verify the location you have selected has adequate ventilation to allow for the proper cooling of the SVR DO NOT BLOCK SVR FANS OR AIR VEN...

Страница 5: ...put load is greater than 75 of the rated output of the SVR BYPASS INDICATOR LED Not on frequency converter models When this LED is lit the SVR bypass is active Should the Alarm LED be lit at the same time the SVR detected an internal failure and must be serviced REGULATOR INDICATOR LED When this LED is lit the SVR inverter is operating and powering the connected load OVER CREST INDICATOR LED This ...

Страница 6: ...tility is present will turn the SVR inverter and output off TO TURN SVR ON CONNECT THE SVR TO UTILITY POWER AND TURN ON THE MAIN CIRCUIT BREAKER DO NOT PRESS THE ON BUTTON LOCATED ON THE FRONT PANEL TO TURN SVR OFF TURN OFF THE MAIN CIRCUIT BREAKER TEST BUTTON Only present on SVR models with internal battery option installed The following describes the different modes of operation for this button ...

Страница 7: ...ted there will be one short beep WHEN SVR FRONT PANEL BUTTON DEPRESSED 2 Category Two Alarms Three short beeps indicates the SVR output voltage is out of proper operating range SVR OUTPUT VOLTAGE OUT OF PROPER RANGE Four short beeps indicates the SVR output frequency is out of proper operating range SVR OUTPUT FREQUENCY OUT OF PROPER RANGE Five short beeps indicates the SVR is in an over temperatu...

Страница 8: ...Up GREEN MODE OFF Default NOTE THE SVR MUST BE TURNED OFF AND BACK ON BEFORE NEW DIP SWITCH SETTINGS WILL BECOME ACTIVE WARNING REFER THE SERVICING OF THIS EQUIPMENT TO QUALIFIED SERVICE PERSONNEL ONLY WARNING NEVER SERVICE THIS UNIT WHILE THE POWER IS APPLIED HIGH VOLTAGE EXISTS AND A HAZARD OF ELECTRICAL SHOCK IS PRESENT WARNING THIS DEVICE IS INTENDED FOR ADMINISTRATION AND LAB USE NOT INTENDED...

Страница 9: ...l Input Power Circuit Breaker On the rear panel Cooling Vents Must not be obstructed REAR VIEW SVR1K 1T OPTIONAL EXTERNAL BATTERY CONNECTOR OUTPUT RECEPTACLES 6 places without external battery option 4 places as shown COVER PLATE FOR OPTIONAL SNMP AGENT DIP SWITCHES RS 232 CONNECTOR COOLING FAN DO NOT BLOCK INPUT CIRCUIT BREAKER POWER INLET ...

Страница 10: ...ECTOR COOLING FAN DO NOT BLOCK INPUTFUSE POWER INLET COVER PLATE FOR OPTIONAL SNMP AGENT DIP SWITCHES RS 232 CONNECTOR COOLING FANS DO NO BLOCK MAIN POWER SWITCH INPUT CIRCUIT BREAKER INPUT LINE CORD OUTPUT FUSES 2 places OPUTPUT RECEPTACLES 6 NEMA 5 15R STANDARD OTHER OUTPUT RECEPTACLE CONFIGURATIONS ARE AVAILABLE Optional Receptacle Configuration Shown Contact Factory For Other Configurations ...

Страница 11: ... OPTIONAL SNMP AGENT DIP SWITCHES RS 232 CONNECTOR COOLING FANS DO NOT BLOCK MAIN POWER SWITCH INPUT CIRCUIT BREA KER LINE CORDINLET OUTPUT FUSES 2 places OPUTPUT RECEPTACLES Shown with 1 L6 20R 2 5 20R Receptacles OTHER OUTPUT RECEPTACLE CONFIGURATIONS AVAILABLE ...

Страница 12: ...RM TO ANY AFFIRMATION OR PROMISE FOR THIS PRODUCT AND THE USER AGREES THAT IN NO EVENT SHALL FALCON ELECTRIC INC BE LIABLE FOR CONSEQUENTIAL OR INDIRECT DAMAGES LIMITS OF LIABILITY LIMITATION OF LIABILITY THERE IS NO LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL LOSS OR DAMAGE UNDER THESE WARRANTIES INCLUDING BUT NOT LIMITED TO LIABILITY FOR INJURY LOSS OF LIFE PROPERTY DAMAGE LOSS OF USE LOSS OF DATA...

Страница 13: ...Azusa Canyon Road Irwindale CA 91706 800 842 6940 626 962 7770 Fax 626 962 7720 service falconups com Should service be desired you must first obtain a Return Material Authorization number RMA and shipping instructions from our customer service department Please have your SVR Series model and serial number s on hand prior to the call This information is located on the identification label on the r...

Отзывы: