*941367-00*

941367-00

Motorized Electric Latch Retraction

MEL 24/25 Series

Installation Instructions

Remove end cap

These instructions are for MEL conversion kits or MEL 

devices with preinstalled motors.

Parts

Do not discard

MEL 6' cable with motor cable

(47269206)

MEL motor mounting

4-20 x 

¹⁄₄

" FHP screws (qty 2)

Motor cable

only

(114320)

MEL motor

assembly

MEL

cover plate

Allegion Connect accessories available to order
106198  MEL-CON adapter cable with 8-pin connector
040069  MEL motor cable + MEL-CON adapter cable with 8-pin  

 connector

 

If MEL is preinstalled in the device: 

If installing the MEL conversion kit, follow 

the instruction steps as written. 

Mark and Prepare 2 Holes

a

b

c

#25

#10-24

Wood/Madera/Bois

Metal/Metal/Métal

¹⁄₈

" (3 mm) x 1" (25 mm)

Follow original device instruction up to the point 

where this end mounting bracket step has been 

completed. 

A.

Complete MEL wiring per steps 15-21 of this 

instruction. 

B.

Return to original device instruction at point you left 

off, and complete installation. 

C.

Содержание MEL 24 Series

Страница 1: ...available to order 106198 MEL CON adapter cable with 8 pin connector 040069 MEL motor cable MEL CON adapter cable with 8 pin connector If MEL is preinstalled in the device If installing the MEL conver...

Страница 2: ...on a table or bench remove the 2 screws that connect mechanism case to center case Use long shank screwdriver 6 Unhook baseplate from center case a Slide back mechanism case about 2 to access hooking...

Страница 3: ...3 7 Slide baseplate out of mechanism case baseplate 8 Remove any existing dogging assembly d e f Slide m...

Страница 4: ...down from baseplate the hook arm should sit on the near side of that post Rotate the motor assembly to hook the arm over the baseplate axle pin that is closest to the baseplate Do not pull out on moto...

Страница 5: ...while sliding mechanism case onto baseplate b 11 Reconnect center case to baseplate via hooking parts 12 Insert remaining pushbar guide nearest the center case and slide mechanism case against center...

Страница 6: ...res c Plug cable connector into MEL motor d Reinstall end mounting bracket e Refer to table below to route proper gauge wires from electric hinge EPT or door loop to PS900 Series power supply c d Dia...

Страница 7: ...ption 1 Option 3 Option 2 Option 1 PS902 1 Board PS904 914 2 Boards PS906 3 Boards 1 a Review Available 900 series Option Board Mounting Locations Gray PS902 PS904 PS914 PS906 1 1 2 2 3 1 Plug Option...

Страница 8: ...50 60Hz Input I1 will activate both outputs Input I1 will activate output 1 Input I2 will activate output 2 MEL Device 1 PS900 Series PS900 Series MEL Device 2 Note Fail secure output only allowed if...

Страница 9: ...ain OR remove and reapply power to clear condition 24 VDC low LED flashing green Latchbolt retracted Voltage low during latchbolt retraction latchbolt retracts at reduced force Wire length is too long...

Страница 10: ...10 21 Install MEL cover plate Do not cut from recessed end of cover plate back of new MEL cover plate back of old cover plate recessed area Install this end first recessed end...

Страница 11: ...11 22 Reinstall end cap 23 Reinstall center case cover...

Страница 12: ...y CAUTION Cautions indicate potentially hazardous conditions which if not avoided or corrected may cause minor or moderate injury Cautions may also warn against unsafe practices Notices indicate a con...

Отзывы: