Falcon L 540 720 Скачать руководство пользователя страница 6

15

GB

• Replace the 

fi

 lter support

•   Screw  the 

fi

 lter support using the 2 screws 

12c 

(2,9 x 6 ,5) pro-

vided.

•   Replace the grease 

fi

 lters  make sure that the handle is visible on 

the outside.

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a 

fl

 exible or rigid 

pipe ø 150 or 120 mm, the choice of which is left to the installer.
•   To install a ø 120 mm air exhaust connection, 

insert the reducer 

fl

 ange

  9

 on the hood body 

outlet.

•  Fix the pipe in position using suf

fi

 cient pipe 

clamps (not supplied).

•   Remove any activated charcoal 

fi

 lters.

RECIRCULATION VERSION AIR OUTLET

•   Drill a hole ø 120 or 150 mm in the shelf above the hood 

and connect the hood canopy outlet to the top part of 
the wall unit by means of a rigid or 

fl

 exible pipe of the 

same diameter, the choice of which is at the discretion 
of the installer.

•   To install a ø 120 mm air exhaust connection, insert the 

reducer 

fl

 ange

 9

 on the hood body outlet.

•   Fix the pipe in position using suf

fi

 cient pipe clamps (not 

supplied).

•  Ensure that the activated charcoal 

fi

 lters  have  been 

inserted.

ELECTRICAL CONNECTION

•  Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 

mm.

ø 150

9

ø 120

150

120

9

12c

Содержание L 540 720

Страница 1: ...Instruction Manual GB ...

Страница 2: ......

Страница 3: ...ee of aeration must be guaranteed in the room in order to pre vent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for dome stic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never leave hi...

Страница 4: ...1 Hood Body complete with Controls Light Blower Filters 9 1 Reducer Flange ø 150 120 mm Ref Q ty Installation Components 12c 2 Screws 2 9 x 6 5 Q ty Documentation 1 Instruction Manual 1 Electric Diagram L L1 400 370 175 240 240 ø150 Hood Type 54 72 L 540 720 L1 512 692 12c 9 ...

Страница 5: ...for a support panel thickness of between 15 mm and 30 mm Cut a fitted opening in the bottom surface of the wall unit as shown Remove the metal grease filters see par on Maintenance Disconnect the filter support by turning the internal handles provided Insert the hood until the side supports snap into place Lock in position by tightening the screws Vf from underneath the hood 375 L2 Vf Hood Type 54...

Страница 6: ...g sufficient pipe clamps not supplied Remove any activated charcoal filters RECIRCULATION VERSION AIR OUTLET Drill a hole ø 120 or 150 mm in the shelf above the hood and connect the hood canopy outlet to the top part of the wall unit by means of a rigid or flexible pipe of the same diameter the choice of which is at the discretion of the installer To install a ø 120 mm air exhaust connection inser...

Страница 7: ...ushed for about 2 seconds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons S1 Led Fixed Indicates that the Metal grease filters saturation alarm has been triggered and the filters need to be washed The alarm is triggered after 100 working hours Reset check the Maintenance paragraph Flashing indicates that the activa...

Страница 8: ...eset Switch of the lights and extractor motor Press button T3 for at least 3 seconds until the leds start to flash Cleaning the filters The filters are washable and must be cleaned when led S1 flashes or at least every 2 months of operation or more frequently for particularly heavy usage Remove the filters one at a time supporting them with one hand and turning the safety knobs pull and turn Wash ...

Страница 9: ...rm can be enabled on installation or at a later date Turn the Lights and the suction Motor off Disconnect the Hood using the Main switch or the double pole switch on the mains power sup ply Restore the connection by pressing and holding T1 Release the button All five LEDs are turned on Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation LED flashes twice Activated charcoal filter ...

Отзывы: