background image

G2522 Grill 
 
Installation and Servicing 
Instructions 

 

The  appliance  must  be  installed  and  serviced  by  a  qualified  person  as  stipulated  by  the  Gas 

Safety 

(Installation & Use) 

Regulations.

 

 

IMPORTANT

 

The installer must ensure that the installation of the appliance is in conformity with these instructions  and 

National Regulations in force at the time of installation. Particular attention MUST be paid to: 

 

Gas Safety 

(Installation & Use) 

Regulations

 

Detailed recommendations are contained in 

Institute of Gas Engineers published documents:

 

Health And Safety At Work etc. Act

 

Local and National Building Regulations  Fire 
Precautions Act

 

IGE/UP1

IGE/UP/2

 

BS6173 

and 

BS5440

 

 

The  appliance  has  been  CE-marked  on  the  basis  of  compliance  with  the  Gas  Appliance  Directive  for  the 
Countries, Gas Types and Pressures as stated on the data plate.

 

WARNING

TO PREVENT SHOCKS, ALL APPLIANCES WHETHER 

GAS OR ELECTRIC,  MUST BE EARTHED.

 

On  completion  of  the  installation,  these  instructions  should  be  left  with  the  Engineer-in-Charge  for reference 
during  servicing.  Further  to  this,  The  Users  Instructions  should  be  handed  over  to  the  User,  having  had  a 
demonstration of the operation and cleaning of the Appliance.

 

 

IT  IS  MOST  IMPORTANT  THAT  THESE  INSTRUCTIONS  BE  CONSULTED  BEFORE  INSTALLING  AND 
COMMISSIONING  THIS  APPLIANCE.  FAILURE  TO  COMPLY  WITH  THE  SPECIFIED  PROCEDURES 
MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

 

 

PREVENTATIVE MAINTENANCE CONTRACT

 

In  order  to  obtain  maximum  performance  from  this  unit  we  would  recommend  that  a  maintenance  contract 
be  arranged  with 

SERVICELINE

.  Visits  may  then  be  made  at  agreed  intervals  to  carry  out  adjustments and 

repairs. A quotation will be given upon request to the contact numbers below.

 

 

WEEE Directive Registration No. WEE/DC0059TT/PRO  

At end of unit life, 

dispose of appliance and any replacement  parts in a safe manner, via a licensed 
waste handler.

 

Units are designed to be dismantled easily and recycling of all  material is 
encouraged whenever practicable.

 

 

 

 

Falcon Foodservice Equipment

 

HEAD OFFICE AND WORKS

 

Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.

 

 
SERVICELINE CONTACT

 

Phone: 01438 363 000 

Fax: 01438 369 900 

 

 

T100576 Ref. 4 

Содержание G2522

Страница 1: ...the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of the Applianc...

Страница 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where...

Страница 3: ...ied out 1 3 Ventilation The grill MUST be installed level in a well lit and draught free position Adequate ventilation whether natural or mechanical must be provided to ensure sufficient air for combu...

Страница 4: ...ing or Flexible hose must not exceed 1 5m in length 1 5 Electrical Supply Not applicable to this appliance 1 6 Water Supply Not applicable to this appliance 1 7 Heat Inputs Natural I2h and Propane I3p...

Страница 5: ...Unpack grill and check that all components are undamaged Parts supplied loose are specified in the contents list below Brander Drip Trough Brander Plate Grid Shelf Drip Tray Gas Governor Natural Gas o...

Страница 6: ...Remove RH Side Panel b Fit a pressure gauge to test point and light grill c With burner at Full Flame position setting pressure should be as detailed in Section 1 9 On Natural gas models adjust gover...

Страница 7: ...ng and pilot injectors Remove governor and check supply pressure accordingly section 1 9 Adjust aeration Adjust Low flame Turndown setting section 2 5 3 Change data plate To Convert from PROPANE to NA...

Страница 8: ...1 To Remove Proceed as follows a Remove control knob and front facia panel bottom fixing nuts Pull facia panel lower edge forward then downwards to remove facia panel b Remove RH outer side panel view...

Страница 9: ...und on the data badge A list of items available together with codes is as follows Description Part No Plaque single 531600010 Thermocouple 531600030 Pilot burner body 531600050 Pilot orifice Natural G...

Отзывы: