SECTION 1 - GENERAL DESCRIPTION 

 

Training and competence  

To help ensure the safe use of this appliance there is a requirement for you to provide whatever information, 
instruction, training and supervision as is necessary to ensure, so far as is reasonably practicable, the health 
and safety of all users. 

For  further  help  and  information  on  training  and  competence  we  would  refer  you  the  Health  and  Safety 
Executive  website; 

www.hse.gov.uk

  document  ref:  health  and  safety  training  INDG345.  International 

customers should default to the health and safety guidelines provided by your government body. 

Risk assessment  

As  part  of  managing  the  health  and  safety  of  your  business  you  must  control  any  risks  identified  in  your 
commercial kitchen. To do this you need to think about what might cause harm to people and decide whether 
you  are  taking  reasonable  steps  to  prevent  that  harm.  This  is  known  as  risk  assessment.  It  is  important  to 
consider the environment around the product as well as the product itself. For example oil or food spills will 
present a  significant  risk so users  so the need to immediately clean up such spills  must be reflected in  staff 
training. 

For  further  help  and  information  on  risk  assessments  we  would  refer  you  to  you  the  Health  and  Safety 
Executive  website

www.hse.gov.uk

 document  ref: risk assessment INDG163. International customers should 

default to the health and safety guidelines provided by your government body. 

 
WARNING 

 

UNDER NO CIRCUMSTANCES MUST THE BURNER BE TURNED ON WHEN PAN IS EMPTY, NOR 
SHOULD IT BE LEFT TO BOIL DRY

 

FAILURE TO OBSERVE THIS MAY INVALIDATE THE WARRANTY. 

 

 
The boiling pan is provided with a strainer to fit in pan bottom and also a lift off cover. This can be 
stored inside mounted rack when not in use. A swivel tap may be provided if specified. The arm is of 
sufficient length to enable inner pan of a dual purpose model to be filled also. A side mounted filler 
funnel is provided on dual purpose units. The lift-off cover fits both inner and outer pans of a dual 
purpose model. 
The gas tap has a built-in flame failure device. In the event of pilot being extinguished or the mains 
gas being turned off for any reason, the burner will shut down until lighting procedure is undertaken 
again. A spark igniter is provided to light pilot, and a mirror is located below pan to enable pilot and 
burner to be monitored. 
An easy to clean drain tap is fitted to all models. 
 
 

 

 

 

 

      Removable lid 

 
 Swivel water tap 
 

 

 

 

  

   Inner lift out pan 

 
 Filler funnel 
 (optional) 
 

 

 

 

 

      Drain tap  

 

 

 

 

 

       

 Spark igniter 
 

 

 

 

 

      Gas control 
       

 

 

 

 

 

Gas inlet 

 

 

 

 

Mirror    

Safety cut out  

  

 

 

 

 

 

Re-set button   

 

 

 

 

Figure 1 

 

Содержание G2078

Страница 1: ...afety Regulations in particular the need for regular servicing by a competent person to ensure the continued safe and efficient performance of the Appliance WARNING TO PREVENT SHOCKS ALL APPLIANCES WHETHER GAS OR ELECTRIC MUST BE EARTHED Upon receipt of the User s Instruction manual the installer should instruct the responsible person s of the correct operation and maintenance of the Appliance Thi...

Страница 2: ...tion on risk assessments we would refer you to you the Health and Safety Executive website www hse gov uk document ref risk assessment INDG163 International customers should default to the health and safety guidelines provided by your government body WARNING UNDER NO CIRCUMSTANCES MUST THE BURNER BE TURNED ON WHEN PAN IS EMPTY NOR SHOULD IT BE LEFT TO BOIL DRY FAILURE TO OBSERVE THIS MAY INVALIDAT...

Страница 3: ...is evident when inner pan is clamped in position Inner PAN This should be filled to no more than outer pan brim level GAS CONTROL Figure 2 There are four set operating positions as illustrated Position 1 Burner pilot OFF Position 2 Pilot ignition or Pilot ON only Position 3 Burner FULL ON Position 4 Burner ON at LOW rate Due to a built in safety stop it is necessary to push knob inward before tryi...

Страница 4: ... resetting Safety cut out if pan has been recently used as base and flue will be extremely hot Unscrew black plastic cover from centre spindle of safety cut out Insert suitably sized pin screwdriver or other such article into hole in red centre spindle Gently push to check if click can be heard and or felt If so the safety cut out has been re set If not the safety cut out has not required re setti...

Страница 5: ... handle and raise rear edge first This will direct steam away from operator Lift cover to a vertical position to allow condensation to drip back into pan and store in side mounted rack The food should then be removed from pan into a smaller serving receptacle such as a bain marie container or a deep gastronorm container Warning This transfer manoeuvre should be carried out using a ladle or baler T...

Страница 6: ...rain Tap This is specially designed to be dismantled for cleaning Warning Never attempt to dismantle drain tap when there is liquid in either the inner or outer pan Ensure that the drain tap is cold before dismantling To Dismantle a Lift handle b Turn tap fully clockwise to stop c Lift handle and inner tap straight up d Turn further clockwise till stop is hit e Push inner tap and handle down into ...

Отзывы: