background image

ON

4

3

2

1

OF

F

ON

4

3

2

1

OF

F

ON

4

3

2

1

OF

F

ON

4

3

2

1

OF

F

1

2

L3

L2

SA

FE

TY

RE

LA

Y

23

23

24

33

34

34

35

35

36

36

37

37

38

40

44

GP

P

G

27

SE

TT

ING

 1 &

 2 O

N

SE

TT

IN

G 2

 O

N

SE

TT

IN

G 1

 O

N

SE

TT

IN

G A

LL

 O

FF

P

G

P

G

28

32

LIN

 IN

PU

T

27

29

39

26

26

33

32

30

30

31

20

25

40

38

CO

NT

RO

L

SW

ITC

H

C(2

)

CO

NT

RO

L

SW

ITC

H

B(1

)

CO

NT

RO

L

SW

ITC

H

A(

0)

AM

BE

R

NE

ON

RE

D

NE

ON

SA

FE

TY

T/S

TA

T

CO

OL

IN

G

FA

N

17

18

28

29

CO

NT

RO

L

SW

ITC

H

D (

3)

61

60

59

58

53

52
51

50

54

55

56

57

62
63
64

65

64 65

63

62

61

60

59

58

57

56

55

54

53

52

51

50

Wire

 45

Wire

 46

IN+

Out 

1

+

Out 

2

+

11

14

A2

    A

1

CH

AN

NE

L A

 (0

)

CH

AN

NE

L C

(2)

CH

AN

NE

L D

(3)

CH

AN

NE

L B

(1)

1

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

16

16

17

18

19

19

20

25

41

42

43

44

45

45

46

46

48

48

47

47

BR

OW

N

US

E T

WO

 TE

RM

IN

AL

S

FO

R 0

.5m

CA

BL

E

LA

BE

LE

9F

 +

WI

RE

S 4

, 5 

& 6

 TO

 BE

 TW

IST

ED

TO

GE

TH

ER

 BU

T N

OT

 TW

IST

ED

TH

RO

UG

H F

ER

RIT

E B

EA

D

12

P6

65

P5

EN

L1

CA

PA

CIT

OR

12

2

24

31

41

42

43

22 21

GR

EY

 CA

BL

ES

 N

OT

US

ED

. C

UT

 SH

OR

T

AN

D T

AP

E U

P

BL

UE

BL

AC

K

BL

UE

BR

OW

N

FE

RR

ITE

BE

AD

OP

ER

AT

IN

G

RE

LA

Y

FUS

E 2A

OV

EN

LA

MP

S

EA

RT

H

PO

ST

MC

B

40

A

WI

RE

S 1

,2 &

 3 T

O B

E

TW

IST

ED

 TO

GE

TH

ER

B(1

)

C(2

)

D(

3)

A(

0)

TH

ES

E W

IRE

S T

BE

SH

EA

TH

ED

 AN

D

RO

UT

ED

 RO

UN

BA

CK

OF

 UN

IT 

AN

D U

P L

EF

T

HA

ND

 SI

DE

SECTION 6 - E3913i / E3914i WIRING DIAGRAM

9

Содержание E3913i

Страница 1: ...he appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a maintenance contract be arranged with SERVICELINE Visits may the...

Страница 2: ...Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems due to customer misuse Lubrication and adjustment of door ca...

Страница 3: ...th lamps operate correctly SECTION 1 INSTALLATION UNLESS OTHERWISE STATED PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1 1 MODEL NUMBER NETT WEIGHT and DIMENSIONS 1 2 SITING The appliance should be installed in a well lit position on a firm level non combustable floor Where unit is to be positioned in close proximity to a wall partition kitchen furnit...

Страница 4: ...user and ensure that the person s responsible understand the instructions regarding correct operation and cleaning of the appliance Particular emphasis should be given to Regular cleaning of air filter Suitable pan type Keeping cooking zones free from all objects particularly metal utensils at all times The user must also be made aware of potential to heat jewellery and disrupt electronic equipmen...

Страница 5: ...EP 5 Figure 3 Carefully lift and remove top frame ceran glass plate assembly and lay it upon a flat surface If replacing hob in the event of glass damage ensure any glass debris is cleared away from induction coils and from inside of unit Ensure that no coil spacers have been removed or disturbed when removing glass panel If this occurs then these must be restored to their respective locations Rep...

Страница 6: ...FUSE THERE ARE NO SERVICEABLE PARTS WITHIN THE GENERATOR BOX DO NOT ATTEMPT TO GAIN ENTRY TO GENERATOR AS THIS WILL INVALIDATE WARRANTY AFTER REPLACEMENT THE FAULTY GENERATOR UNIT MUST BE RETURNED COMPLETE AND INTACT TO FALCON FOODSERVICE EQUIPMENT Remove louvred front panel to gain access to generator refer to Section 3 3 Relays MCB and fuse are accessible at rear of slide assembly To remove gene...

Страница 7: ...ion 10 Use a clamp meter to measure the following data Note If any current is outwith these tolerances the cause must be investigated and rectified 5 2 1 E3913i Range Induction Hob Only Terminal I Actual I Max I Min L1 20 3A 21 4A 18 2A L2 20 3A 21 4A 18 2A L3 20 3A 21 4A 18 2A Total 60 9A 64 2A 54 6A 7 5 2 3 E3913i With Oven Switched On Terminal I Actual I Max I Min L1 29A 30 45A 26 1A L2 29A 30 ...

Страница 8: ...es blocked Fan filter clogged Temperature sensor faulty external heat sources too close Clear air routes Clean fan filter Remove any external heat source If all OK replace generator 07 Cooking zone temperature sensor Short circuit at temperature sensor Test coil sensor Replace coil assembly 08 Mains phase failure Fault in mains supply Test mains supply 10 Communication error Failure in LIN or CAN ...

Страница 9: ...e 45 Wire 46 IN Out 1 Out 2 11 14 A2 A1 CHANNEL A 0 CHANNEL C 2 CHANNEL D 3 CHANNEL B 1 1 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 18 19 19 20 25 41 42 43 44 45 45 46 46 48 48 47 47 BROWN USE TWO TERMINALS FOR 0 5mm CABLE LABELED 9F WIRES 4 5 6 TO BE TWISTED TOGETHER BUT NOT TWISTED THROUGH FERRITE BEAD 1 2 P6 6 5 P5 E N L1 CAPACITOR 1 2 2 24 31 41 42 43 22 21 GREY ...

Страница 10: ...ATOR GREEN INDICATOR RH REAR DIL SWITCH 1 2 ON RH FRONT DIL SWITCH 2 ON LH FRONT DIL SWITCH ALL OFF LH REAR DIL SWITCH 1 ON A 0 B 1 C 2 D 3 LIN INPUT 400V 3N SUPPLY DRAWN WITH NO SERVICES DELIVERED CONTINUED 38 39 40 19 31 18 18 20 20 27 32 27 30 40A MCB OVEN LAMPS OVEN FAN 28 25 24 17 37 7 12 15 9 11 14 36 OR SR CONTINUED OVEN ELEMENTS 3 2 1 6 5 4 Out 1 Out A2 A1 RELAY 41 FUSE 2A 42 COOLING FAN 1...

Отзывы: