3.2 CONTROL SWITCHES - TO REPLACE
If a control switch is faulty it is not normally repairable.

The switch must be replaced adopting the following

procedure:
Remove the control panel as detailed in Section 3.1.
Remove the switch connections, noting the

arrangements of the cables.
Pull off the control knob and undo the switch fixing

screws to release the switch.
Fit the new switch in reverse order. Ensure that the

earth bonding wire(s) is attached to it.

3.3 PILOT LAMPS - TO REPLACE
If a lamp is faulty it is not normally repairable. The

indicator must be replaced adopting the following

procedure:

Remove the control panel as detailed in Section 3.1.
Pull off the lamp connections. Undo the nut which

secures the lamp at the rear and remove.

3.4 HOTPLATE - TO REPLACE
Remove the control panel as detailed in Section 3.1.
Slacken the two nuts inside the ends of the chrome

plated side trims.
Pull the hob assembly forward to release the front

fixing and swing it upward, pivoting at the rear. Prop

the plate up in the raised position.
Undo the connections to the hotplate, noting their

locations.
Remove the central fixing nut to allow the plate to be

withdrawn from the top.
Replace in reverse order.

4

3

1

2

5

P2

P1

P3

4

3

1

2

5

P2

P1

P3

Hotplates

Six Position Switches

Red Neon

E350/32 WIRING DIAGRAM

Содержание E350/32

Страница 1: ...ration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be...

Страница 2: ... Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems due to cus...

Страница 3: ...y cuts off part of the element circuit should the plate become overheated due to being left on without a pot on it Controls 6 heat switches SECTION 2 ASSEMBLY and COMMISSIONING a Place the appliance in position and carefully level it by using the feet adjusters if it is to be mounted on a counter or table If the unit is required to be mounted on the special purpose stand please refer to the instru...

Страница 4: ...ust be replaced adopting the following procedure Remove the control panel as detailed in Section 3 1 Pull off the lamp connections Undo the nut which secures the lamp at the rear and remove 3 4 HOTPLATE TO REPLACE Remove the control panel as detailed in Section 3 1 Slacken the two nuts inside the ends of the chrome plated side trims Pull the hob assembly forward to release the front fixing and swi...

Страница 5: ...4 3 1 2 5 P 2 P 1 P 3 4 3 1 2 5 P 2 P 1 P 3 4 3 1 2 5 P 2 P 1 P 3 4 3 1 2 5 P 2 P 1 P 3 H o t p l a t e s S i x P o s i t i o n S w i t c h e s R e d N e o n E 3 5 0 3 3 W I R I N G D I A G R A M ...

Отзывы: