SECTION 3 - SERVICING
Before attempting any maintenance, isolate unit at main switch. Take steps to ensure that it cannot
inadvertently be switched on.
3.1 MAINS INDICATOR LAMP
An indicator neon is located on the control panel and must be replaced if failure occurs. Undo
bottom fixing and remove panel. Ease panel down from behind top facia. Remove 2 lamp
connections. Connect replacement neon and replace control panel.
3.2 ELEMENTS
These units are fitted with a number of identical elements which may be replaced individually.
To replace a faulty element, proceed as follows:
Undo back panel access plate fixings and remove panel.
Remove fixings from both sides of element mounting bracket, gaining access from the front of the
unit.
Undo fixings which secure element to rear inner panel and withdraw element.
Fit replacement element and replace additional parts in reverse order.
3.3 ENERGY REGULATOR
Remove knob and control panel. Undo screws which secure regulator to control panel and remove
regulator. Note wire connection locations and transfer each to corresponding position on the
control. Fit replacement control to panel and re-fit panel.
3.4.1 RELAYS
Undo right hand side panel fixings and remove panel.
Undo fixings which secure relay to bracket and remove relay.
Note wire connections and locations and transfer each to the corresponding position on the new
relay. Replace outer side panel.
SECTION 4. SPARES
When ordering spare parts, always quote appliance type and serial number.
This information will be found on data badge attached to right hand outer side panel.
Element 240V
731540400
Neon red
730962010
Relay
731570004
Energy regulator
737630011
Control knob
731570001