IMPORTANT INFORMATION 

 
Warranty Policy Shortlist 
 

Warranty does not cover :- 
 

Correcting faults caused by incorrect installation of a product. 
Where an engineer cannot gain access to a site or a product. 
Repeat commission visits. 
Replacement of any parts where damage has been caused by misuse. 
Engineer waiting time will be chargeable. 
Routine maintenance and cleaning. 
Gas conversions i.e. Natural to Propane gas. 
Descaling of water products and cleaning of water sensors where softeners/ conditioners are not fitted,  or 
are fitted and not maintained. 
Blocked drains 
Independent steam generation systems. 
Gas, water and electrical supply external to unit. 
Light bulbs 
Re-installing vacuum in kettle jackets. 
Replacement of grill burner ceramics when damage has been clearly caused by misuse. 
Where an engineer finds no fault with a product that has been reported faulty. 
Re-setting or adjustment of thermostats when unit is operating to specification. 
Cleaning and unblocking of fryer filter systems due to customer misuse. 
Lubrication and adjustment of door catches. 
Cleaning and Maintenance: 

 

Cleaning of burner jets 

 

Poor combustion caused by lack of cleaning 

 

Lubrication of moving parts 

 

Lubrication of gas cocks 

 

Cleaning/adjustment of pilots 

 

Correction of gas pressure to appliance. 

 

Renewing of electric cable ends. 

 

Replacement of fuses 

 

Corrosion caused by use of chemical cleaners. 
 
 
 

Electrical Safety and Advice Regarding Supplementary Electrical Protection 

 

Commercial kitchens and foodservice areas are environments where electrical appliances may be located 
close to liquids, or operate in and around damp conditions, or where restricted movement for installation and 
service is evident. 

 

The installation and periodic inspection of the appliance should only be undertaken by a qualified, skilled and 
competent electrician; and connected to the correct power supply suitable for load as stipulated by the 
appliance data label. 

 

The electrical installation and connections should meet the necessary requirements to local electrical wiring 
regulations and electrical safety guidelines. 

 

We recommend:- 

 

 

Supplementary electrical protection with use of a residual current device (RCD). 

 

 

Fixed wiring appliances incorporate a locally situated switch disconnector to connect to, which is 
easily accessible for switching off and safe isolation purposes. The switch disconnector must meet 
the specification requirements of IEC 60947. 

 

 

Содержание DOMINATOR PLUS G3106 Series

Страница 1: ...tion these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of...

Страница 2: ...ts Poor combustion caused by lack of cleaning Lubrication of moving parts Lubrication of gas cocks Cleaning adjustment of pilots Correction of gas pressure to appliance Renewing of electric cable ends...

Страница 3: ...ould be taken not to disturb the air combustion admission and evacuation of open top burner models 1 3 VENTILATION Adequate ventilation must be provided to supply sufficient fresh air for combustion a...

Страница 4: ...el and is identified by the following symbol and must only be used for bonding purposes 1 6 HEAT INPUTS NATURAL and PROPANE GAS kW net Btu hr gross 1 6 1 Total Inputs Model kW Btu hr G3106 41 3 155 00...

Страница 5: ...pplied refer to user instructions for details Important note this should be operated on a low flame setting only 2 1 2 Flue Accessory A tall flue is available as an accessory that may be substituted f...

Страница 6: ...6 Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Fixings...

Страница 7: ...C 10 C If reading is outwith specified range the thermostat may be faulty In this case unit should be serviced see thermostat replacement and calibration procedure Turn gas supply to oven OFF and allo...

Страница 8: ...ect gas supply after all conversion work has been completed Natural to Propane Remove governor from appliance inlet pipework Propane to Natural Fit governor to appliance inlet pipework and follow deta...

Страница 9: ...s and undo fixings along underside and top Pull facia panel forward while slightly easing bottom edge upward to remove 3 2 2 To Remove Open Top Hob Components Remove pan supports and burner heads comp...

Страница 10: ...ition system controller it is not replaceable Full replacement of controller is necessary 3 6 OVEN IGNITERS and ELECTRODES The oven ignition system is electronically controlled Access to ignition syst...

Страница 11: ...overnor be aware that unburned gas may be vented occasionally to release pressure on diaphragm This should not be confused with a gas leak 3 11 FAULT CHECK LIST If a flame is not established on any bu...

Страница 12: ...12 Circuit Diagram...

Страница 13: ...13 Wiring Diagram...

Отзывы: