9
3.1.3 Oven Burner - To Replace Injector
a) Remove oven shelves and base plate.
b) Disconnect Gas supply pipe.
c) Unscrew and remove existing injector.
d) Insert and screw in replacement injector.
e) Re-connect Gas supply pipe.
3.1.4 Thermostat - To Replace Bypass Screw (Figure 7)
a) Remove control panel.
b) Unscrew and remove existing bypass screw from
thermostat.
c) Insert replacement bypass screw and secure into
thermostat.
d) Re-assemble in reverse order.
3.1.5 Solid Top Burner - To Replace Injector (Figure 9)
a) Remove solid top castings.
b) Release pilot assembly from burner.
c) Remove burner.
d) Unscrew and remove existing injector.
e) Insert and screw in replacement injector.
f) Refit burner and ensure burner aeration adjustment.
(see Section 1.10)
Pilot injector
a) Remove pilot pipe from pilot assembly.
b) Remove existing pilot injector from pilot pipe.
c) Fit replacement injector over pipe
d) Refit pilot pipe to pilot assembly.
e) Refit pilot assembly to burner.
f) Leave solid top castings off to allow manometer to be fitted to burner test point.
3.1.6 Resetting Low Rate Screw (Figure 10)
a) Remove control panel.
b) Fit manometer to burner test point.
c) Connect replacement gas supply to appliance.
d) Light solid top burner.
e) While burner is ignited turn solid top tap to the
low flame position.
f ) Turn screw until manometer reading is stated
in the table indicated in Section 1.10.2.
g) Refit control panel.
h) Remove manometer from burner test point,
ensuring no gas leaks. Reassemble solid top
castings.
Ensure data plate with correct information is fitted after conversion.