![Falcon Dominator Plus E3625 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/falcon/dominator-plus-e3625/dominator-plus-e3625_installation-and-servicing-instructions_3279620003.webp)
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS
WHICH HAVE BEEN PROTECTED BY THE
MANUFACTURER ARE NOT TO BE
ADJUSTED BY THE INSTALLER.
1.1 MODEL NUMBERS, NET WEIGHTS
AND DIMENSIONS
Model
Width
(mm)
Depth
(mm)
Height
(mm)
Weight
(kg)
E3625
600
785
526
56.5
E3925
900
785
526
75.5
1.2 SITING
The appliance should be installed on a level, fireproof
surface, in a well lit and draught free position.
If floor is constructed of combustible material, local fire
requirements should be checked to ensure compliance.
If siting against a wall, it must be of a non combustible
material.
If this is not possible these surfaces should be clad in a
suitable non-combustible, heat-insulating material.
Close attention be paid to fire regulations.
1.3 ELECTRICAL SUPPLY
The units are suitable for AC supplies only. Both
models are for use on three phase supplies.
WARNING - THIS APPLIANCE MUST BE EARTHED
1.4 SUPPLY CONNECTION
A suitable mains input cable should be fitted that
conforms to code designation 60245 IEC 57, cable
type H07RN-F.
A suitably rated isolating switch with contact separation of
at least 3mm in all poles must be installed and wiring
executed in accordance with relevant regulations.
We
recommend supplementary electrical protection with the
use of a residual current device (RCD).
Access to mains terminal block is gained by
removing control panel.
1.5 ELECTRICAL RATINGS
Electrical loading is as stated in table below and also
on appliance data plate.
The location of mains isolating switch should be
identified for use in any event of an emergency or during
cleaning.
1.5.1 E3625
Connection
Amps (A)
L1
11
L2
15
L3
11
1.5.2 E3925
Connection
Amps (A)
L1
15
L2
22
L3
22
Connection
Amps (A)
L1
15
L2
22
L3
22
SECTION 2 - ASSEMBLY AND
COMMISSIONING
Note
The following information should be read as applicable to
the unit being assembled.
2.1 ASSEMBLY
a) Position unit. Level it using foot adjusters. To mount
unit upon a purpose built stand, refer to details
supplied with stand.
b) Unit is supplied with terminals for connection to a
suitable mains supply. All wiring must be in accordance
with local regulations.
c) To gain access to terminals, remove control panel and
proceed as follows:
d) Undo and remove upper fixings.
e) Undo fixings below control panel. Remove panel
carefully and set aside.
f) Terminals are now accessible and supply cables can
be fed through rear of unit.
g) After connecting mains supply, replace control panel.