Falcon 25 Series Скачать руководство пользователя страница 3

d.  Reinstall pushbar endcap.

 

L

Do not force endcap. If endcap does not fit easily, verify 

that the switch clip is oriented correctly and the pin is in the 

correct slot (step 6b).

c

a

b

D

Attach wiring to terminal blocks on exit alarm kit board 

as shown.

 

L

Notes about Wiring:

The EI (external inhibit) option uses NO (normally open) dry contacts 

to inhibit the exit alarm.
Closing the access control contacts inhibits the exit alarm. When the 

access control contacts are re-opened, the exit alarm re-arms with 

no delay.
RX, LX, and EI inputs are not polarized.

Gray
Black
Violet

Von Duprin 24 VDC

Power Supply

(Polarity Sensitive Input)

Insulate

unused

wire

EPT 10

24VDC

RX/LX

Switch

EI

EI

NO (normally open)

Access Contol 

Contacts

NC
C
NO

D

J

F

Yellow
Red
Blue

RX Switch

Prior to 2012, the RX wires were 

Red/Yellow/Blue 

(use Red and Yellow).

*

*

 

L

Install exit alarm assembly in exit device.

Reinstall exit device onto door as needed.

Slide battery plug through battery holder.

10 

Slide battery onto holder.

Make sure

polarity 

is correct