Falcon Foodservice Equipment E1808 Скачать руководство пользователя страница 4

1.4

 

PRE

COMMISSIONING

 

CHECK

 

Fill

 

pan

 

with

 

oil

 

to

 

element

 

guard

 

mark.

 

Approximately

 

19

 

litres

 

(4

 

gallons)

 

per

 

pan

 

for

 

E1808

 

and

 

E1848

 

models

 

and

 

39

 

litres

 

(8Ž1

 

/

   

2

 

gallons)

 

for

 

E1838

 

model.

 

Switch

 

on

 

at

 

isolator

 

switch

 

and

 

at

 

fryer

 

control

 

panel

 

switch.

 

Turn

 

thermostat

 

to

 

maximum

 

setting

 

and

 

check

 

that

 

it

 

operates

 

when

 

oil

 

heats

 

up.

 

If

 

possible,

 

the

 

fryer

 

operator

 

should

 

be

 

made

 

familiar

 

with

 

its

 

use

 

and

 

the

 

importance

 

of

 

never

 

switching

 

on

 

unless

 

elements

 

are

 

covered

 

must

 

be

 

stressed.

 

SECTION

 

2

 ‐ 

MAINTENANCE

 

BEFORE

 

ATTEMPTING

 

ANY

 

MAINTENANCE,

 

SWITCH

 

OFF

 

AT

 

THE

 

MAIN

 

ISOLATING

 

SWITCH

 

AND

 

TAKE

 

STEPS

 

TO

 

ENSURE

 

THAT

 

IT

 

IS

 

NOT

 

INADVERTENTLY

 

SWITCHED

 

ON.

 

 

2.1

 

ELECTRICAL

 

CONTROL

 

GEAR

 

The

 

terminals,

 

contactor

 

and

 

thermostats

 

are

   

contained

 

within

 

a

 

box

 

at

 

the

 

front

 

of

 

the

 

unit.

 

To

 

gain

 

access,

 

open

 

door

 

and

 

remove

 

cover

 

panel

 

behind.

 

The

 

control

 

and

 

neon

 

lamps

 

are

 

mounted

 

on

 

facia

 

panel,

 

this

 

is

 

secured

 

by

 

two

 

fixings.

 

2.2

 

NEON

 

INDICATOR

 

LIGHTS

 

These

 

must

 

be

 

replaced

 

by

 

new

 

lights

 

in

 

event

 

of

 

failure.

 

To

 

remove

 

a

 

faulty

 

neon,

 

first

 

remove

 

facia

 

panel.

 

Undo

 

fixings

 

through

 

trim,

 

ease

 

panel

 

and

 

trim

 

down

 

then

 

withdraw.

 

Pull

 

off

 

snap

on

 

light

               

connectors

 

and

 

remove

 

neon

 

by

 

undoing

 

fixing

 

nut.

 

2.3

 

THERMOSTATS

 

The

 

fryer

 

has

 

an

 

electronic

 

control

 

thermostat

 

and

 

an

 

electro

mechanical

 

safety

 

thermostat.

 

Both

         

adjustable

 

control

 

thermostat

 

and

 

safety

 

thermostats

 

are

 

mounted

 

inside

 

front

 

of

 

fryer.

  

Access

 

is

 

gained

 

by

 

removal

 

of

 

control

 

cover

 

plate.

 

The

 

safety

 

thermostat

 

is

 

designed

 

to

 

cut

 

power

 

to

 

the

 

elements

 

if

 

oil

 

temperature

 

exceeds

 

230Žo

 

C.

 

Manual

 

intervention

 

is

 

required

 

to

 

re

set

 

control

 

in

 

event

 

of

 

cut

out.

 

Re

set

 

button

 

is

 

located

 

at

 

bottom

 

of

 

control

 

compartment,

 

accessible

 

by

 

opening

 

fryer

 

door.

 

2.3.1

  

Users'

 

Thermostat

 

a)

  

Remove

 

control

 

panel.

 

b)

  

Remove

 

control

 

cover

 

plate

 

by

 

undoing

 

four

 

fixings

 

on

 

E1808

 

model

 

and

 

E1838

 

and

 

E1848

 

models.

 

Disconnect

 

electrical

 

leads

 

and

 

leads

 

to

 

potentiometer.

 

c)

  

Undo

 

fixings

 

that

 

secure

 

PCB

 

and

 

withdraw.

 

d)

  

Replace

 

in

 

reverse

 

order.

 

e)

 

To

 

check

 

thermostat

 

calibration,

 

select

 

a

 

temperature

 

of

 

190°C

 

and

 

allow

 

oil

 

to

 

heat

 

up.

 

With

 

a

 

suitable

 

thermometer

 

or

 

thermocouple,

 

immersed

 

25mm

 

below

 

oil

 

surface

 

at

 

pan

 

centre.

 

Check

 

that

 

oil

 

temperature

 

corresponds

 

with

 

setting.

 

Содержание E1808

Страница 1: ...the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURE...

Страница 2: ...s Poor combustion caused by lack of cleaning Lubrication of moving parts Lubrication of gas cocks Cleaning adjustment of pilots Correction of gas pressure to appliance Renewing of electric cable ends...

Страница 3: ...le phase supply is specified the appropriate copper bridging plate is supplied with appliance It is important that connections are made exactly as shown in the following diagram Cable entry is at rear...

Страница 4: ...move a faulty neon first remove facia panel Undo fixings through trim ease panel and trim down then withdraw Pull off snap on light connectors and remove neon by undoing fixing nut 2 3 THERMOSTATS The...

Страница 5: ...to flange on control panel e Withdraw safety thermostat probe by undoing nut from boss on fryer body Ensure that oil has been drained from pan Withdraw capillary and probe from pan f Replace in rever...

Страница 6: ...r 2 6 GENERAL NOTE After any maintenance task check unit to ensure correct performance Carry out any adjustments necessary as detailed in Section 1 Installation 2 7 SPARE PARTS When ordering spare par...

Страница 7: ...E1808 WIRING DIAGRAM...

Страница 8: ...E1838 WIRING DIAGRAM...

Страница 9: ...E1848 WIRING DIAGRAM...