FALCOM SAMBA 75 Скачать руководство пользователя страница 9

SAMBA 75 USER’S GUIDE 

VERSION 1.01 

1 SECURITY 

IMPORTANT FOR THE EFFICIENT AND SAFE OPERATION OF YOUR GSM-MODEM, READ 

THIS INFORMATION BEFORE USE! 
 
Your cellular engine SAMBA 75 is one of the most exciting and innovative electronic 

products  ever  developed.  With  it  you  can  stay  in  contact  with  your  office,  your 

home, emergency services and others, wherever service is provided. 
This chapter contains important information for the safe and reliable use of the 

SAMBA 75 modem. Please read this chapter carefully before starting to use the 

cellular engine SAMBA 75. 

1.1 General information 

Your SAMBA 75 device utilizes the GSM standard for cellular technology. GSM is a 

newer radio frequency („RF“) technology than the current FM technology that has 
been used for radio communications for decades. The GSM standard has been 

established for use in the European community and elsewhere. Your SAMBA 75 is 

actually a low power radio transmitter and receiver. It sends out and receives radio 
frequency energy. When you use your modem, the cellular system handling your 

calls controls both the radio frequency and the power level of your cellular modem. 

1.2  Exposure to RF energy 

There has been some public concern about possible health effects of using a GSM 
modem. Although research on health effects from RF energy has focused for many 

years on the current RF technology, scientists have begun research regarding newer 

radio technologies, such as GSM. After existing research had been reviewed, and 
after compliance to all applicable safety standards had been tested, it has been 

concluded that the product is fit for use. 
If you are concerned about exposure to RF energy there are things you can do to 
minimize exposure. Obviously, limiting the duration of your calls will reduce your 

exposure to RF energy. In addition, you can reduce RF exposure by operating your 

cellular modem efficiently by following the guidelines below. 

1.3  Efficient modem operation 

In order to operate your modem at the lowest power level, consistent with 

satisfactory call quality please take note of the following hints. 

 

If your modem has an extendible antenna, extend it fully. Some models 

allow you to place a call with the antenna retracted. However, your 

modem operates more efficiently with the antenna fully extended. 

 

Do not hold the antenna when the modem is „IN USE“. Holding the 

antenna affects call quality and may cause the modem to operate at a 

higher power level than needed. 

1.4  Antenna care and replacement 

 

This confidential document is a property of FALCOM GmbH and may not be copied or circulated without previous permission. 

Page 8 

Do not use the modem with a damaged antenna. If a damaged antenna comes 

into contact with the skin, a minor burn may result. Replace a damaged antenna 

immediately. Consult your manual to see if you may change the antenna yourself. If 

Содержание SAMBA 75

Страница 1: ...This document is available at HTTP WWW FALCOM DE SAMBA 75 User s manual Version 1 01 18 10 2005...

Страница 2: ...ATION 10 2 SAFETY STANDARDS 11 3 TECHNICAL DATA 12 3 1 GENERAL SPECIFICATIONS OF SAMBA 75 12 3 1 1 Power consumption 14 4 INTERFACES IN OVERVIEW 15 4 1 1 1 Interface A 4 pin USB Type A connector 15 4...

Страница 3: ...GET STARTED 22 6 2 1 Installing your SAMBA 75 on a Laptop computer running Windows XP 22 6 2 1 1 How to use SAMBA 75 phone with a terminal software only 23 6 2 1 2 Setup HyperTerminal program 25 6 2...

Страница 4: ...te Version number Author Changes 29 09 2005 1 00 Fadil Beqiri Initial version 18 10 2005 1 01 Fadil Beqiri Chapter 7 RF Exposures added This confidential document is a property of FALCOM GmbH and may...

Страница 5: ...e available at the following Internet address http www falcom de Trademarks Some mentioned products are registered trademarks of their respective companies Copyright SAMBA 75 user s guide is copyright...

Страница 6: ...provides an integrated SIM card reader and an internal GSM antenna The physical interface to the modem application is made through an embedded USB connector It consists of 4 pins required for control...

Страница 7: ...SET s delivery package Available upon request 0 3 Used abbreviations Abbreviation Description ETSI European Telecommunications Standards Institute GSM Global System for Mobile communications IMEI Inte...

Страница 8: ...PDP Packet Data Protocol RF Radio Frequency ASIC Application Specific Integrated Circuit RTC Real Time Clock Table 1 Used abbreviations 0 4 Related documents 1 ETSI GSM 07 05 Use of Data Terminal Equ...

Страница 9: ...many years on the current RF technology scientists have begun research regarding newer radio technologies such as GSM After existing research had been reviewed and after compliance to all applicable s...

Страница 10: ...nt is adequately shielded from RF energy 1 8 Medical electronic equipment Consult the manufacturer of any personal medical devices such as pacemakers hearing aids etc to determine if they are adequate...

Страница 11: ...boats fuel or chemical transfer or storage facilities and areas where the air contains chemicals or particles such as grain dust or metal powders Do not transport or store flammable gas liquid or expl...

Страница 12: ...nd recommendations for the protection of public exposure to RF electromagnetic energy established by government bodies and professional organizations such as directives of the European Community Direc...

Страница 13: ...2 2 GSM class Small MS Transmit power Class 4 2 W at EGSM 850 and 900 Class 1 1 W at GSM1800 and GSM 1900 GPRS connectivity GPRS multi slot class 12 GPRS mobile station class B EDGE connectivity EDGE...

Страница 14: ...SMS MT MO CB Text and PDU mode SMS storage SIM card plus 25 SMS locations in the mobile equipment Transmission of SMS alternatively over CSD or GPRS Preferred mode can be user defined Audio interfaces...

Страница 15: ...ations and network coverage 3 1 1 Power consumption POWER CONSUMPTION Typ Unit Description GSM GPRS EDGE engine Supply voltage 5 0 V Average supply current MODE BAND 48 mA IDLE mode GSM 900 850 48 GSM...

Страница 16: ...4 1 1 1 Interface A 4 pin USB Type A connector The power supply for the SAMBA 75 modem has to be a single voltage source of 5 V If GPRS EDGE data transfer is in progress please use the Y cable which i...

Страница 17: ...ctionalities are described in chapter 4 2 on this interface see figure below Figure 3 Status indicator of modem 4 1 1 3 Interface C SIM Card interface The SIM interface controls a 3V SIM card This int...

Страница 18: ...r run in SLEEP mode 600 ms On 600 ms Off No SIM card inserted or no PIN entered or network search in progress or ongoing user authentication or network login in progress 75 ms On 3 s Off Logged to net...

Страница 19: ...els The NON CYCLIC SLEEP mode AT CFUN 0 disables the AT interface The CYCLIC SLEEP modes AT CFUN 5 6 7 8 and 9 alternatively activate and deactivate the AT interfaces to allow permanent access to all...

Страница 20: ...le has entered Normal mode Detailed explanations on AT SCFG AT CFUN AT CALA can be found in 3 5 2 1 1 Reset SAMBA 75 via AT CFUN Command To reset and restart the SAMBA 75 use the command AT CFUN You c...

Страница 21: ...ion in EGPRS Multislot Class 10 GPRS Multislot Class 10 and GPRS Multislot Class 12 If the board temperature increases to the limit specified for restricted operation1 while data are transmitted over...

Страница 22: ...rk dependent In extreme cases if it takes too much time for the network and the temperature cannot drop due to this delay the module may even switch off This confidential document is a property of FAL...

Страница 23: ...M card which is provided by your mobile phone service provider This contains the telephone number of SAMBA 75 will use as well as other customer information If your SIM is larger credit card size it m...

Страница 24: ...on software SAMBA 75 phone supports a configuration software named PhoneTool which offers an easy and quickly way to start up following operations send and receive e mails and SMS synchronize your pho...

Страница 25: ...installation example is F Select the Driver folder and click the Open button You will be back to the follow dialog box and then click OK The selected manufacturer s installation driver is being instal...

Страница 26: ...erminal program see figure in subsection below or another terminal program The AT Command Set is also included in the delivery CD See related documents 3 6 2 1 2 Setup HyperTerminal program START PROG...

Страница 27: ...M card The PIN code is usually supplied with the SIM card If you enter an incorrect PIN code three times in a row you will need a PUK Personal Unblocking Key code to unblock the SIM card The PUK code...

Страница 28: ...our computer Remember to select the SAMBA 75 phone as the modem in each application The data transfer and fax functions depend on the applications you have chosen not on the computer or the SAMBA 75 p...

Страница 29: ...sted and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a...

Страница 30: ...ming If this has not been done contact your GSM provider When in regions where GPRS is not available a user can still access their important information with GSM 14 4 kbps data connections 3 I can not...

Страница 31: ...nctions To use some advanced call functions such as call divert call barring or call waiting you need to subscribe them to your operator This confidential document is a property of FALCOM GmbH and may...

Отзывы: