SAMBA 55/56
VERSION 1.03
Shock duration: 1 msec
1 shock per axis
6 positions (± x, y and z)
Dry heat
Temperature: +70 ±2 °C
Test duration: 16 h
Humidity in the test chamber: < 50 %
EN 60068-2-2 Bb
ETS 300019-2-7
Temperature
change (shock)
Low temperature: -40 °C ±2 °C
High temperature: +85 °C ±2 °C
Changeover time: < 30 s (dual chamber
system)
Test duration: 1 h
Number of repetitions: 100
DIN IEC 68-2-14
Na
ETS 300019-2-7
Damp heat cyclic
High temperature: +55 °C ±2 °C
Low temperature: +25 °C ±2 °C
Humidity: 93 % ±3 %
Number of repetitions: 6
Test duration: 12 h + 12 h
DIN IEC 68-2-30
Db
ETS 300019-2-5
Cold (constant
exposure)
Temperature: -40 ±2°C
Test duration: 16 h
DIN IEC 68-2-1
Table 4:
Summary of reliability test conditions
This confidential document is the property of FALCOM GmbH and may not be copied or circulated without permission.