Please be careful when removing and installing the Island installation Brackets and Stainless Steel chimneys.
The Stainless steel chimneys contains sharp edges and can possibly lead to cuts.
Generally asked Questions and Answers:
1. Q: My extractor fan is not extracting
A:
before logging a service call please ensure the installation on your extractor fans was done properly to
avoid a service call out fee charge. Herewith a list of commonly found mistakes on everyday installations:
* Installer did not remove the tape on the butterfly valve. (Q: 13).
*
Installer did not secure the power cord inside the chimney. (Q: 13).
*
Your ducting hose is exceeding the recommended maximum length. (Q: 13).
*
Your unit is not at the recommended height. (Q: 3).
*
Your unit is installed above the wrong application. (Q: 2).
A service fee will apply when we log a service call and any of the points above apply.
2. Q: Can I use the extractor fan above my gas braai?
A:
NO. Please note that this unit was designed for the intended purpose of domestic kitchens only and cannot
be used as a commercial extractor fan. Commercial usage includes but is not limited to: Restaurants, Coffee
Shops, Soup Kitchens, Tuck shops, Food trailers, Gas
braai’s inside or outside your property, any other form
of braai and any kitchen that is used for commercial purposes. Using the extractor you purchased on any
commercial application poses a serious fire risk and will result in immediate void of your warranty. Please
contact our Falco offices for assistance with Gas Braai Extractors.
3. Q: What is the correct installation height?
A:
The recommended installation height is 700mm above gas and 650mm above electrical. On either
application it is recommended that your installation height does not exceed 750mm to ensure the best results.
Q: Do I require a recirculation kit?
A:
No. The extractor was designed to be used on both applications; External and Re-circulation air operation
and no additional kit are required.
4. Q: What is the difference between External and Re-circulation air operation?
A: Re- circulation;
All wall mount units are supplied with aluminium and charcoal filters. For Re-circulation
mode you will simply install the unit. The air will filtrate through both sets of filters, you’re outside aluminium
filters
and
you’re inside charcoal filters.
The air discharged from your extractor is then clean and grease free
and cannot cause any damage. There are two options when using your extractor on Re-circulation. 1
– Let the
filtrated air escape through the vents on top of your top chimney or you can use the extendable ducting house
to vent the air into your ceiling.
in the charcoal filters removes odour and some smoke
particles from the air before releasing the cleaned air back into the kitchen.
•
External:
The only difference between Re-circulation mode and external mode is that on external mode you
are venting the air to the outside of your property using a ducting hose. This means the clean filtrated air will
not be discharged into your kitchen or ceiling but to the outside. The unit is supplied with an extendable
ducting hose. When venting your air outwards the charcoal filters can be removed to improve the suction rate.
Removing the charcoal filters on re-circulation mode is not recommended.
|
Please note that the wall fitting that fits into your wall when venting your air outwards is not supplied
with the extractor and can be purchased locally.