Please be careful when removing and installing the Island installation Brackets and Stainless Steel chimneys. 
The Stainless steel chimneys contains sharp edges and can possibly lead to cuts. 

Generally asked Questions and Answers: 

1. Q: My extractor fan is not extracting

A: 

before logging a service call please ensure the installation on your extractor fans was done properly to

avoid a service call out fee charge. Herewith a list of commonly found mistakes on everyday installations:
* Installer did not remove the tape on the butterfly valve. (Q: 13).

*

Installer did not secure the power cord inside the chimney. (Q: 13).

*

Your ducting hose is exceeding the recommended maximum length. (Q: 13).

*

Your unit is not at the recommended height. (Q: 3).

*

Your unit is installed above the wrong application. (Q: 2).

A service fee will apply when we log a service call and any of the points above apply.

2. Q: Can I use the extractor fan above my gas braai?

A: 

NO. Please note that this unit was designed for the intended purpose of domestic kitchens only and cannot

be used as a commercial extractor fan. Commercial usage includes but is not limited to: Restaurants, Coffee
Shops, Soup Kitchens, Tuck shops, Food trailers, Gas 

braai’s inside or outside your prope

rty, any other form

of braai and any kitchen that is used for commercial purposes. Using the extractor you purchased on any
commercial application poses a serious fire risk and will result in immediate void of your warranty. Please
contact our Falco offices for assistance with Gas Braai Extractors.

3. Q: What is the correct installation height?

A: 

The recommended installation height is 700mm above gas and 650mm above electrical. On either

application it is recommended that your installation height does not exceed 750mm to ensure the best results.

Q: Do I require a recirculation kit?
A: 

No. The extractor was designed to be used on both applications; External and Re-circulation air operation 

and no additional kit are required. 

4. Q: What is the difference between External and Re-circulation air operation?

A: Re- circulation; 

All wall mount units are supplied with aluminium and charcoal filters. For Re-circulation

mode you will simply install the unit. The air will filtrate through both sets of filters, you’re outside aluminium

filters 

and

you’re inside charcoal filters.

The air discharged from your extractor is then clean and grease free

and cannot cause any damage. There are two options when using your extractor on Re-circulation. 1 

 Let the

filtrated air escape through the vents on top of your top chimney or you can use the extendable ducting house
to vent the air into your ceiling.

Activated charcoal

 in the charcoal filters removes odour and some smoke

particles from the air before releasing the cleaned air back into the kitchen.

x

External: 

The only difference between Re-circulation mode and external mode is that on external mode you

are venting the air to the outside of your property using a ducting hose. This means the clean filtrated air will
not be discharged into your kitchen or ceiling but to the outside. The unit is supplied with an extendable
ducting hose. When venting your air outwards the charcoal filters can be removed to improve the suction rate.
Removing the charcoal filters on re-circulation mode is not recommended.
|

Please note that the wall fitting that fits into your wall when venting your air outwards is not supplied
with the extractor and can be purchased locally.

25

Содержание AR-60-701

Страница 1: ...INSTALLATION AND USER S MANUAL Model AR 60 701 AR 90 701 AR 60 736 AR 90 736 AR 60 706RGB AR 90 706RGB...

Страница 2: ...full providing that the product appliance is located no further than 50km from an authorised service agent Where the product appliance is located beyond the 50km radius the purchaser shall be liable...

Страница 3: ...e incorrect size Extractor Fan is installed above any electrical or gas hob Example of such an installation is installing a 600mm Extractor above a 900mm gas or electrical hob 14 This warranty does no...

Страница 4: ...LLATION EXTERNAL DUCTING 6 INSTALLATION AIR RECIRCULATION 10 OPERATION AR 60 701 AR 90 701 11 OPERATION AR 60 736 AR 90 736 15 OPERATION AR 60 706RGB AR 90 706RGB 18 MAINTENANCE 22 TROUBLESHOOTING 24...

Страница 5: ...commercial application The extractor and its filters should be regularly cleaned to avoid any fire hazards due to oil build up in and around the extractor If the supply cord is damaged it must be repl...

Страница 6: ...an be connected as per the picture below to a ducting pipe with an internal diameter of 150mm 2 The extractor should be mounted at the following distances above the counter top Above a gas hob or cook...

Страница 7: ...now mounted wall bracket Certain models will require that additional screws be used to further secure the extractor to the wall this will entail opening up the extractor s front flap removing the alum...

Страница 8: ...5 Fix the provided ducting pipe to the air outlet of the extractor as in the picture below 8...

Страница 9: ...wo chimney sections to the required length Once the required length is determined fix the bracket with the provided screws as shown in the picture below 2 Drill 2 x 8mm holes to accommodate the Plate...

Страница 10: ...to the outside with the ducting pipe is not possible then the ducting pipe can be discarded The installation of the extractor is the same as previously shown the only difference is that carbon filter...

Страница 11: ...ilters are securely locked in place Please note that once the filters are fitted to the extractor the suction power of the unit will decrease somewhat OPERATION Touch control for models AR 60 701 AR 9...

Страница 12: ...as used before it will revert back to its last operation setting The above is the same whether the unit is switched on using the remote control or the control panel on the extractor While the unit is...

Страница 13: ...ong pressing the light button 1 Will turn off the cleaning symbol and reset the total working time of the extractor When the cleaning symbol is displayed 2 Will show the current total working time of...

Страница 14: ...The display will show the following 00 00 while flashing the unit is now in the TIMER MODE Press to 15 minutes Press to decrease 1 minute Press to increase 1 minute To save the setting press and hold...

Страница 15: ...n when the fan is working 2 Time display 3 Timer 4 Light 5 Fan speed 6 Alarm symbol 7 Cleaning symbol appears when total working time reaches 14 hours or at the initial start up OPERATION Touch contro...

Страница 16: ...hile the unit is in STANDBY MODE press the timer button to enter CLOCK SETTING MODE The hour display will flash press and to adjust the hours Press to change to minutes The minutes display will flash...

Страница 17: ...wnlights on and off Long pressing the light button 1 Will turn off the cleaning symbol and reset the total working time of the extractor When the cleaning symbol is displayed 2 Will show the current t...

Страница 18: ...AR 90 706RGB After the plugging the extractor into the power supply the unit will automatically go into STANDBY MODE SPEED INCREASE BUTTON Used to switch on the extractor and to increase the fan spee...

Страница 19: ...etting or wait 10 seconds to save automatically While the unit is in WORKING MODE short press the button to cycle through one of the following timer settings OFF 15 min 30 min 45 min 60min OFF Alterna...

Страница 20: ...f the extractor When the cleaning symbol is not displayed 3 Switching on the Mood Lighting Long press 3 5 seconds the light button This will enter the Mood Lighting Setting Mode One of the following w...

Страница 21: ...n the following will be displayed A2 Mood lighting setting To increase or decrease the intensity of the light simply push either the buttons when the A1 A2 A3 A4 is selected The X values represent the...

Страница 22: ...TENANCE Before cleaning switch off the unit by unplugging from the wall socket or if connected directly to the mains switch off at the isolator switch I REGULAR CLEANING Use a soft cloth moistened wit...

Страница 23: ...soapy water and giving it a very gently clean with a cloth III ANNUAL REPLACEMENT OF THE CARBON FILTERS This only applies to extractors which are recirculating the air back into the kitchen space not...

Страница 24: ...n to the power supply again Serious Vibration of the unit The fan blade is damaged Switch off the unit and repair by qualified service agent The fan motor is not fixed tightly Switch off the unit and...

Страница 25: ...ve gas and 650mm above electrical On either application it is recommended that your installation height does not exceed 750mm to ensure the best results Q Do I require a recirculation kit A No The ext...

Страница 26: ...e for the use of Stainless steel Two great products are window cleaner which is also a stainless steel cleaner and spray on wood polish another certified stainless steel cleaner Please note that abras...

Страница 27: ...rate of your extractor fan If you are out venting the air and the extension of ducting hose exceeds 2 5meter you need to purchase an addition extraction motor that must be installed in line with the d...

Страница 28: ...e environment and human health which could otherwise be caused by inappropriate waste handling of this product The symbol on the product indicates that this product may not be treated as household was...

Отзывы: