background image

Please ensure that if your butterfly valves are fitted, that the tape stuck over your butterfly valves in the factory 
is removed when your unit is installed. Failure to remove the tape on the two butterfly valves will result in 
airflow outlet to be restricted and this will cause the air to be returned causing the blowing of air instead of the 
extraction of air. Before booking a service call make sure you check this first to avoid being charged.

(a)This is a picture of the butterfly valve closed with the tape on top:

The tape should be removed when installed. Both butterfly valves open when the extractor is switched on:

(b) Ducting hoses exceeding the 2.5meters will also have a negative effect on the extraction rate of your extractor fan. 
If you are out-venting the air and the extension of ducting hose exceeds 2.5meter you need to purchase an addition 
extraction motor that must be installed in line with the ducting hose to support in the extraction of the air. The longer 
your ducting hose the less your extraction rate will be. If your ducting hose is too long and you did not install an 
additional extracting motor in line with the ducting hose, your extractor will not extract the air. Please ask your installer 
about an additional inline motor when your ducting hose is exceeding 2.5m. 

14. Q: Parts Availability

A:

Full range of spares is available from Lategan & Van Biljoens in Pretoria. 

www.appliancesspares.co.za

15. Q: What is the diameter of my ducting hose?

A: 

150mm

16. Q: More Queries?

A: 

Please email any queries to:

[email protected]

, Tel: 011 454 6423/4314.

Spares can be viewed and ordered online: 

www.appliancespares.co.za

22

Содержание AR-60-303

Страница 1: ...INSTALLATION AND USER S MANUAL Model AR 60 303 AR 90 303 AR 60 111 AR 90 111 AR 60 501 AR 90 501 AR 120 110...

Страница 2: ...full providing that the product appliance is located no further than 50km from an authorised service agent Where the product appliance is located beyond the 50km radius the purchaser shall be liable...

Страница 3: ...e incorrect size Extractor Fan is installed above any electrical or gas hob Example of such an installation is installing a 600mm Extractor above a 900mm gas or electrical hob 14 This warranty does no...

Страница 4: ...Table of Contents EdZK h d KE dz WZ hd KE E d d KE yd ZE h d E E d d KE Z Z Z h d KE KW Z d KE Z KW Z d KE Z Z KW Z d KE Z Z Z Z D Ed E E dZKh KKd E Z Yh Ed z Yh d KE Es ZKED Ed WZKd d KE 3 3...

Страница 5: ...commercial application The extractor and its filters should be regularly cleaned to avoid any fire hazards due to oil build up in and around the extractor If the supply cord is damaged it must be repl...

Страница 6: ...e below to a ducting pipe with an internal diameter of 150mm 2 The extractor should be mounted at the following distances above the counter top Above a gas hob or cooker 75cm but not exceeding 75cm Ab...

Страница 7: ...e used to further secure the extractor to the wall this will entail opening up the extractor s front flap removing the aluminum filter s and then securing it to the wall using the pre drilled holes at...

Страница 8: ...he one with the vents holes cut into the sides into the bottom section this one is solid with no vent holes 1 Adjust the total chimney length by sliding the two chimney sections to the required length...

Страница 9: ...e plate II onto the wall with the two screws provided Fit the chimney section on top of the extractor and fix it in place with the screws INSTALLING THE CHIMNEYS MODELS AR 60 303 AR 90 303 Slide the t...

Страница 10: ...wo chimney sections to the required length 2 Fix the bottom chimney section to the extractor with the 2 screws 4 x 8mm 3 Slide the chimney sections to adjust the chimney height Once the required heigh...

Страница 11: ...ll with the screws provided 5 Assemble the chimney onto the extractor and fix it with 2 screws INSTALLATION MODEL AR 120 110 1 The extractor should be mounted at the following heights Above a gas hob...

Страница 12: ...by removing all the filters at the bottom of the unit 4 Fit the one way valves to the top of the two air outlets on the extractor fan then attached the two ducting pipes on top of the now fitted one w...

Страница 13: ...upwards to adjust to the correct height Once the required height is reached drill 4 x 8mm holes to accommodate the second bracket Once fixed to the wall the top chimney can be held in place by using...

Страница 14: ...tallation of the extractor is the same as previously shown the only difference is that carbon filters provided assist in trapping capturing odours 1 Attach the carbon filters to the motor of the extra...

Страница 15: ...eam MEDIUM SPEED BUTTON Airflow speed ideal for standard cooking operation HIGH SPEED BUTTON When high levels of smoke are produced during cooking press for highest level of extraction LIGHT BUTTON To...

Страница 16: ...111 After the plugging the extractor into the power supply the unit will automatically go into STANDBY MODE SPEED INCREASE BUTTON Used to switch on the extractor and to increase the fan speed SPEED D...

Страница 17: ...button to switch the downlights on and off Long pressing the light button 1 Will turn off the cleaning symbol and reset the total working time of the extractor When the cleaning symbol is displayed 2...

Страница 18: ...y the grease build up will block the air from flowing through and thereby affect the suction rate of the extractor Clean it by removing from the extractor and submerging into hot soapy water and givin...

Страница 19: ...ight wire Remove the LED board light by unscrewing the x 4 screws 5 Once the downlights have been removed simply disconnect and replace with the same type AR 60 303 AR 90 303 AR 60 501 AR 90 501 MAX 1...

Страница 20: ...n to the power supply again Serious Vibration of the unit The fan blade is damaged Switch off the unit and repair by qualified service agent The fan motor is not fixed tightly Switch off the unit and...

Страница 21: ...ve gas and 650mm above electrical On either application it is recommended that your installation height does not exceed 750mm to ensure the best results Q Do I require a recirculation kit A No The ext...

Страница 22: ...e for the use of Stainless steel Two great products are window cleaner which is also a stainless steel cleaner and spray on wood polish another certified stainless steel cleaner Please note that abras...

Страница 23: ...rate of your extractor fan If you are out venting the air and the extension of ducting hose exceeds 2 5meter you need to purchase an addition extraction motor that must be installed in line with the d...

Страница 24: ...e environment and human health which could otherwise be caused by inappropriate waste handling of this product The symbol on the product indicates that this product may not be treated as household was...

Отзывы: