Figure 4. Shielded, differentially driven 

load for bridge mode operation 

 
The housing of the modulator is connected 
to  the  shield  of  the  cables  this  way, 
resulting  in  good  interference  rejection. 
This  scheme  is  also  the  recommended 
one if the user has the possibility to design 
the connections of the load him/herself. 
 
In  situations  where  driving  the  load 
differentially  with  two  connectors  is 
impossible, e.g. because the load has only 
a  single  connector,  both  amplifier  outputs 
have to be connected together at the load, 
as depicted in Fig. 5.  

 

 

 

Figure 5. Driving a single-connector load 

in bridge mode 

 

If  one  of  the  two  connections  of  the 
connector is connected to the (conductive) 
housing of the load, check that: 

Ÿ

 

the  housing/outside  of  the  load  floats 

with  respect  to  the  ground  of  the 
amplifiers, i.e. it makes no contact with the 
electrical  circuit  to  which  the  amplifiers 
belong,  other  than  via  the  output  cables, 
and 

Ÿ

 

the housing/outside of the load and the 

BNC  connector  itself  cannot  be  touched, 
as  it  carries  the  full  output  voltage  of  one 
of  the  high  voltage  amplifiers.  For  this 

reason  the  sign 

 is  present  on  the 

enclosure.  The  use  of  an  insulated  BNC 
connector is recommended. 
 

To  aid  in  connecting  floating  loads  in 
bridge  mode,  Falco  Systems  offers  a 
special  ‘bridge  mode  insulated  tee-cable’ 
(Fig. 6). This cable takes the two amplifier 
cables  on  BNC  connectors,  and  has  a 
third  BNC  connector,  where  the  inner 
conductor of one input cable is connected 

to the inner pin, and the inner conductor of 
the  other  cable  to  the  outer  ring,  which  is 
normally  associated  with  the  0V  shield. 
This  functionality  is  very  different  from  a 
normal  BNC  tee-adapter,  which  is  only 
used  to  connect  the  inner  conductor  of  a 
BNC  cable  to  two  cables,  with  all  inner 
pins connected together.  

 

 

 

Figure 6. A ‘bridge mode’ tee-cable for 

connecting the load is available from Falco 

Systems, and can be purchased on the 

website 

www.falco-systems.com

 

 
Required amplifier properties 

 

The  WMA-IB-HS  phase  inverter  -  buffer 
can  be  used  with  many  high  voltage 
amplifiers,  and  is  not  limited  to  driving 
amplifiers  of  the  Falco  Systems  brand. 
Most  amplifiers  with  an  output  current 
limiter  are  suitable,  as  the  current  limiter 
will  ensure  that  the  maximum  power 
dissipation  inside  the  amplifier  will  not  be 
exceeded.  When  the  setup  is  used  with 
fast  changing  signals,  the  voltage  and 
current  transients  at  the  amplifier  outputs 
may  be  slightly  different  in  bridge  mode 
than when the load is grounded. For most 
amplifiers  this  will  be  no  problem,  but 
when  in  doubt,  please  contact  the 
manufacturer of the high voltage amplifiers 
before using the amplifiers in bridge mode.  
Amplifiers  without  a  current  limiter  will 
dissipate  twice  the  normal  power.  The 
double  voltage  will  be  shared  equally 
between the amplifiers in bridge mode, but 
the  doubled  voltage  across  the  load  will 
result  in  a  doubled  current,  which  flows 
through both amplifiers. Depending on the 
details of the setup, this higher dissipation 
may  or  may  not  be  a  problem.  Again, 
when  in  doubt,  please  contact  the 
manufacturer  of  the  amplifiers  before 
using the amplifiers in bridge mode.   
 

 
 
 

Load 

Cable 1 

Cable 2 

Shielding enclosure 

Load 

Cable inner 
conductor 

Enclosure 

Cable outer  
shield 

Cable 

Содержание WMA-IB-HS

Страница 1: ...IB HS is switchable to 100k input impedance and to 50 The 50 setting is used with 50 sources such as function or arbitrary waveform generators to ensure waveform integrity even at high operating frequ...

Страница 2: ...with the high speed phase inverter buffer connected to two high voltage amplifiers to drive them in bridge mode When two amplifiers are driven in bridge mode the high voltage output signal with twice...

Страница 3: ...ther cable to the outer ring which is normally associated with the 0V shield This functionality is very different from a normal BNC tee adapter which is only used to connect the inner conductor of a B...

Страница 4: ...ypical 50 source such as a function or arbitrary waveform generator has a 50 output and will form a 1 2 voltage divider with the 50 input resistance of the WMA IB HS To prevent the loss in signal ampl...

Страница 5: ...antenna This product should only be cleaned with a soft slightly moist cloth Disconnect the phase inverter buffer from the power supply and all equipment before cleaning Safety The WMA IB HS high spe...

Страница 6: ...litude is restored by the 2x gain of the WMA IB HS 9c Corresponding inverted output signal Figure 9 1MHz 20Vpp square wave output signal at the buffered and inverted outputs 50 input impedance setting...

Страница 7: ...11b Noise at the inverted output Figure 11 Output noise AC coupled with a 50 shielded BNC dummy load on the input with the input switched to 50 impedance Frequency Hz Gain 1 2 1 0 0 8 0 6 0 4 0 2 0 0...

Страница 8: ...to indicate compliance of this equipment with the European Union safety and EMC regulations while the mark has been added to indicate compliance with the United States FCC regulations WEEE and RoHS D...

Страница 9: ...User manual version 1 5 Date October 29 2018 Falco Systems Falco Systems Remisestraat 1 2225 TH Katwijk aan Zee The Netherlands Tel 31 0 6 21840996 Fax 31 0 20 2031445 Email info falco systems com ww...

Отзывы: