1

2

3

!

In/Ex

Attach holder to the wall in a location convenient for the user.

Put batteries in the controller

Prepare device which is to be operated (see Product User Manual)

Screw holder firmly to the wall with the use

of anchor pins.

Put the ZWK controller onto the holder

Make sure that the device is appropriately installed and plugged in to power supply.

Make sure that you have physical access to programming button and device manual

operating button.

Make sure that the device operates appropriately by pressing manual operating button.

Make sure that the network status LED on the device which is to be added to controller

lights up. If the network status LED does not emit light it means that the device is not

plugged in to power supply (manual operation does not work) or it has already been

assigned to the same or other controller.

Note! In devices powered by photovoltaic panel (AMZ Z-Wave Solar awning blind, ARZ Z-

Wave Solar roller shutter) the network status LED should light up for 5 sec. after pressing P

button what means readiness to assign device to the network.

Preparing controller for programming

Содержание ZWK10

Страница 1: ...www fakro com ZWK10 Z Wave Controller User Manual 14 06 30 NC852 GB ENGLISH ...

Страница 2: ... of movement 7 Controller programming basic functions 8 Adding device to the controller INCLUDE 8 Adding device only to buttons of movement ASSOCIATE 8 Adding another controller to the Z Wave network LEARN MODE 9 Removing device from the controller EXCLUDE 10 Restoring the controller to factory settings DEFAULT 10 Removing one device from buttons of movement DELETE 11 Removing group of devices fro...

Страница 3: ...troller operates up to 10 devices separately on 5 channels 2 devices for 1 channel It also allows for creation of 10 independent groups Each group can include several devices operated simultaneously Controller s memory can contain up to 231 devices The ZWK10 controller is equipped with a two way Z Wave radio communication module exploiting radio wave frequency frequency depending on the country fo...

Страница 4: ... or group of devices OPEN STOP CLOSE Groups of controlled devices group 1 2 channel 1 group 3 4 channel 2 group 5 6 channel 3 group 7 8 channel 4 group 9 10 channel 5 Programming button IN EX Basic press button of movement or within 0 5 sec in order to cause the device to move and press in order to stop the device Multilevel press button or and hold until the device reaches desired position and th...

Страница 5: ...he Z Wave network are divided into operating devices controllers and devices controlled e g servo motors Single controlled device can operate only within one network single HomeID and one network can include only one basic PRIMARY controller overriding In order to add second controller it must be set as SECONDARY subordinate When configuring devices to operation in the network address HomeID is as...

Страница 6: ...utton Make sure that the device operates appropriately by pressing manual operating button Make sure that the network status LED on the device which is to be added to controller lights up If the network status LED does not emit light it means that the device is not plugged in to power supply manual operation does not work or it has already been assigned to the same or other controller Note In devi...

Страница 7: ...sure proper operation of the device wait 10sec Now controller is ready to operate Note If one omits step 2 that is pressing button of movement the device will be added only to the network see INCLUDE function Then to be able to operate the device it is necessary to add it to buttons of movement with the use of ASSOCIATE function Controllerprogramming quick configuration In order to add another dev...

Страница 8: ...If device has already been assigned to the controller for buttons of movement group it can be added to another group with the use ofASSOCIATE function Controllerprogramming basic functions Adding device to the controller INCLUDE Adding device only to the controller s memory is required if the user wants device to be in the Z Wave network and operated e g only by subordinate controller SECONDARY Pr...

Страница 9: ...N EX button on additional remote control until lighting of LEDs 1 and 3 Within 10 sec on basic remote control LEDs 2 and 3 will light up and on additional 2 and 4 will light up If the sequence does not occur perform the procedure from the beginning Note With the use of an additional controller SECONDARY it is not possible to add device to the network INCLUDE and remove device from the network EXCL...

Страница 10: ...n to another controller below presented procedure must be performed But one should bear in mind that this procedure will remove device from buttons of movement and controller s memory Controllerprogramming basic functions Resetting the controller will cause removing of all devices from its memory and the change of unique HomeID network address for a new one Removing devices from the controller wil...

Страница 11: ...ttons of movement without removing it from the network This function is used for removing all devices from buttons of movement of a given group without removing them from the network Choose channel on the controller from which group of devices is to be removed Within 1 sec press twice IN EX button and once any button of movement of a given group until LEDs 1 2 3 light up Within 10 sec confirm remo...

Страница 12: ...contact with each other or time to perform ASSOCIATE procedure is too short Within 1 sec press IN EX button and once SELECT button on PRIMARY controller LEDs 1 and 2 will light up Within 10 sec press P button on the device until LEDs on the controller change into 3 and 4 On the target controller SECONDARY e g ZWMA module within 60 sec choose channel and perform ASSOCIATE function within 1 sec pres...

Страница 13: ...o be operated see device manual until LEDs on the controller change into 1 2 3 4 If a given sequence of LEDs does not occur it is necessary to perform procedure again This function allows for copying group of devices from PRIMARY controller to SECONDARY controller and conversely within one network Associating Z Wave devices ASSOCIATE DEVICE Copying group of devices COPY GROUP Choose channel and wi...

Страница 14: ...epending on the surrounding environmenta Range ofZ Wave devices Radio signal range depends on the type of construction the materials used and the Z Wave devices location Penetration of the radio signal in different materials 1 Brick wall 60 90 2 Reinforced concrete 20 60 3 Wooden structures of gypsum cardboard 80 95 4 Glass 80 90 5 Metal walls 0 10 ...

Страница 15: ...led within the warranty period will be removed free of charge no longer than 14 days after accepting the product for repair Warranty and post warranty repairs are performed by the manufacturer i e FAKRO PP Sp z o o Quality Certificate Device Model Serial Number Seller Address Date of Purchase Signature stamp of installing person Declaration of Conformity in accordance with directive 2006 95 EEC We...

Страница 16: ...FAKRO PP Sp z o o ul Wegierska 1 44A 33 300 Nowy Sacz Polska www fakro com tel 48 1 8 444 0 444 fax 48 1 8 444 0 333 14 06 30 NC852 GB 2014 FAKRO ...

Отзывы: