Remote
– calibration possible after
prior recalibration of the device. It is
possible via gate (Gateway Z-Wave),
remote control with a display, e.g.
ZRS24 remote control (FAKRO).
1. Discalibrate device from
controller – set parameter 12, value 2
Light
-
2. Calibrate device from controller –
set parameter 12, value 1
Flashing...
-
3. Press UP button and hold it till
reach first end position.
Flashing...
-
4. Press STOP button to confirm first
end position.
Stop flashing and lit
cointinously within 2 sec.
-
5. Press DOWN button and hold it
till reach second end position.
Flashing...
-
6. Press STOP button to confirm
second end position.
Stop blinking and lit
cointinously within 2 sec.
-
4. Association Groups.
There are four association groups in awning blind AMZ Solar:
1.
Life Line – group for position reporting awning blind after each a stoppage and alarm reporting (overcurrent, damage
encoders). This group can be a maximum 1 device.
2.
Basic Repeat – group used to transfer the received basic commands to the devices included in this group. This group can be a
maximum 5 devices.
3.
Multilevel Repeat – group used to transfer the received multilevel commands to the devices included in this group. This
group can be a maximum 5 devices.
4.
Basic Control – group used to transfer the received commands from AMZ Solar (A, S mode) to the devices included in this
group. This group can be a maximum 5 devices.
5. Compatibility of other producers’ appliances in Z-Wave.
Z-Wave allows for the integration of other producers’ appliances for lighting, heating, domestic automatic appliances, etc. The Z-
Wave works in the network as a “repeater”, which enlarges the range of radio communication. The more appliances in the network,
the more resistant to disordered activities in the network.
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery
operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network
Launch the “INCLUDE” procedure with a controller of the existing network, and then press the “Programming button” located on the
awning blind which you want to link to the network.
Attention: All information concerning “Include” and “Associate” options in other producers’ controllers can be found in their
user manuals.
6. Z-Wave configuration parameters.
No.
Value
Default
Value
Size
Description
1
0x00,
0x01,
0x02
0x00
1
00 – manual
01 – semi
02 – auto
2
0x01,
0x02
0x01
1
01 – summer
02 – winter
3
0x01...
0x03
1
time [min]
02.03.18 NC97B-GB 5/8 ©2018, FAKRO