background image

6

In the Power menu the power setting can be changed by means of the plus/minus buttons in steps up to the Power-Limit (PLim, EF-

Menu/Heater) value or down to 5W respectively. If the wrap-around is activated, the setting rolls over at the PLim/5W border. When wrap-

around is disabled, further increase or decrease is blocked at the borders. The Power-Limit value is adjusted in the Extended Functions 

Sub-Menu “Heater” and provides a protection feature for atomizers which are not prepared for high wattage or to reduce the power range 

intentionally. 

The wattage step size is 1 Watt below 20W, 2W from 20W to 40W and 5W above 40W, but can 

be set to 0.5W, 1W and 2.5W respectively in the mod-menu with “Half Watt=1”.

Note: In temperature control mode (TC-mode) the Power setting defines the permitted power for 

the heating up phase of the coil. If the power level is smaller than the value needed to achieve 

the selected temperature, the operation changes from a temperature regulator to a temperature 

limiter. Keep this in mind, if the mod doesn’t reach the expected temperature. If the power level is sufficiently high, it sets the heating 

up speed of the coil until the set-point temperature is reached. After the heating up phase, the power is reduced automatically by the 

temperature controller. 

In the operation mode “Bypass” (mechanical mod), changing the power setting is not available, because the power is defined by the 

battery voltage and coil resistance. The menu “Power” is not displayed in this case, but the value display during and after the vape shows 

the actual power output to the coil. 

When the battery voltage decreases, power is reduced starting from the voltage set by the parameter UbatMin (EF-mod menu) plus 0.5V 

and ending at 10W at UbatMin. E.g. UbatMin=2.5V and Power=40W => Full 40W until battery voltage is at 3.0V, and then reduced to 

34W at 2.9V, 28W at 2.8V and so forth. When the power is reduced, the battery symbol in the display starts blinking. We recommend 

to set UbatMin between 2.5 and 2.7V.

This Menu item is only available and displayed if temperature controlled vaping is selected (see 

Heater-Control menu item below). So the menu structure adapts to the selected operation mode. 

The Temperature Up/Down menu sets the set point for the coil temperature during vaping. The 

temperature set point can be selected from 120°C to 280°C (250°F- 540°F) in steps of 5°C (10°F). To achieve a high precision tempera-

ture control, a correctly performed reference measurement (TempCal Init) is mandatory, see next item.

This Menu item is only displayed if temperature controlled vaping is selected (see Heater Control 

menu item below). For the use of temperature controlled vaping, the calibration measurement 

is a very important part of it. 

The Temperature calibration measures the coil resistance at room temperature (20°C) as the 

reference for temperature controlled vaping. This together with the wire’s temperature coefficient enables the mod to calculate the coil’s 

temperature. The calibration must be confirmed in a second step to avoid accidental activation. After confirmation the display shows 

“process” until the calibration completed. It is extremely important to understand, that, if the calibration is performed at a temperature 

other than 20°C, the control will regulate a constant temperature, but with an offset deviation. So take the ambient temperature during 

the temperature adjustment in to account. Similar, if a wrong temperature coefficient was adjusted, the actual temperature might deviate 

dramatically from the set-point (here it is a factor and not an offset).

Always perform a calibration, when a new atomizer is attached, even if it is made from the same coil material.  For further information 

about this topic, please read the “Application Note for Temperature Controlled Vaping”, available on the dicodes website.

This is a display only menu item. The coil resistance is displayed in a range from 0.00 to 9.90 

Ohms. If temperature controlled vaping is selected, the current measured coil temperature is 

also displayed, if not, the display shows T ---. 

If the display does not show 20°C even with cooled down atomizer, it is recommended to per-

form a manual calibration again. 

Note that for coils with very low resistance, like Nickel-coils, a slight mechanical rearrangement (tightening the atomizer) can lead to dra-

matic changes in the temperature control due to the change of contact resistances. We therefore recommend to use other than Nickel 

coils, e.g. The NiFe30 (RESISTHERM) wire from dicodes. Operation Modes

5.

 Menu Overview

5.4 Changing the Power Setting

5.5 Setting the Temperature

5.6 Manual Coil Temperature Calibration

5.7 Coil Resistance and Coil Temperature

Содержание Illusia C

Страница 1: ...ILLUSIA C USER MANUAL ...

Страница 2: ...ft Button OLED Screen Size 26 mm Output Power 5 60 W Output Current 18 A max Output Voltage 10 V max Single 18650 20700 or 21700 Li ion battery operation 0 91 Inch OLED display Zero current consumption when switched off Temperature controlled vaping mode with various wire types Mechanical MOD mode protected Fakirsmods Illusia C is equipped with Dicodes BF 60 chipset It is an electronically con tro...

Страница 3: ...ach vape see display mode setting The displayed values depend on the operation mode During temperature controlled vaping the current coil temperature the applied power the wire type coil resistance and the battery charge status battery symbol is displayed Note that all values are permanently updated Use this feature when you want to check the correct operation just press the fire button with actua...

Страница 4: ...lusia C 4 Menu Overview Display during after Vape in TC Mode Temperature of Coil Applied Power Battery charge status Selected Wire Type Current Coil Resistance Voltage with without power The following diagram shows the overall menu structure Main Menu Extended Functions Menu ...

Страница 5: ...ey Lock is displayed To unlock the buttons again both buttons need to be pressed at the same time indicated by Key UnLock shown on the display By means of the plus and minus buttons it is possible to navigate through the menu as well as to increase and decrease values of a parameter after a short waiting until the value is displayed inverted black on white The waiting time from navigation mode to ...

Страница 6: ...t point for the coil temperature during vaping The temperature set point can be selected from 120 C to 280 C 250 F 540 F in steps of 5 C 10 F To achieve a high precision tempera ture control a correctly performed reference measurement TempCal Init is mandatory see next item This Menu item is only displayed if temperature controlled vaping is selected see Heater Control menu item below For the use ...

Страница 7: ...h Other selected the temperature coefficient defined in the Extended Functions Menu under item Tmp Cof is used The value of the selected coefficient is displayed behind Wire For commonly used wires the predefined coefficients are NiFe30 320 Nickel200 620 Ti tanium 350 Tungsten 440 and Stainless Steel 105 Note that there are different alloys for Titanium and Stainless Steel on the market so the pre...

Страница 8: ...me In this case different flavors within the liquid which all develop their taste at different temperatures are all addressed by the varying temperature We recommend to set the normal power not the boost to much lower values when using the periodic boost because the average power is increased by the boosts and temperature gets higher therefore Note If the power setting equals the power limit value...

Страница 9: ...et voltage would be greater than 10V or the set current would be greater than 20A which depends on the coil resistance For example with a coil resistance of 4 Ohms and a power setting of 40W the required voltage at the coil is 12 7V With 4 Ohms the max imum wattage is 25W 12V 4R 25W Or if the coil resistance is 0 1Ohm the maximum power is 40W because 20A 0 1Ohm 40W As can be seen from the examples...

Страница 10: ... rate An initial boost is for quick coil heat up The periodic boost lets the coil temperature pass a certain range all the time In this case different flavors within the liquid which all develop their taste at different temperatures are all addressed by the varying temperature We recommend to set the normal power not the boost to much lower values when using the periodic boost because the average ...

Страница 11: ...and temperature gets higher therefore 0 OvrVolt The input voltage is too high The dicodes 2395 is prepared for the use of one or two batteries If the input voltage exceeds 9V this error message is displayed 1 ChkAtom No atomizer detected or open coil 2 TempRef A problem during the temperature reference measurement occurred Repeat the calibration procedure 4 OverCur Short on coil or coil breakdown ...

Страница 12: ...Fakirs by email prior to sending back the device If a sent back defective device is not covered by the warranty Fakirs will give the customer a quote for repair before any repair action takes place The postal fee or shipping charge from the customer to Fakirs is not covered by the warranty in any case Warranty does not apply to products purchased through unauthorized vendors The warranty does not ...

Страница 13: ...nditions and water Do not drop throw or immerse the device in water Use the proper operating mode according to your atomizer and coil material Do not use this product for other purposes except only for vaping Switch off the device during transport to avoid unintentional firing Do not attempt to repair the product by yourself as damage or personal injury may occur Fakirs Illusia C is a rechargeable...

Страница 14: ...www fakirsmods com info fakirsmods com ...

Отзывы: