For users
- 9 -
3. Technical specification
Model
IXR36
IXR46
IXR56
IXR66
IXR80
Advised pool volume
(m
3
)
25~45
30~55
40~75
50~95
65~120
Working air temp ( )
℃
-15~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
in Smart mode
11.0
14.0
18.0
22.0
27.5
Heating capacity (kW)
in Booster mode
13.0
17.0
21.5
26.0
32.0
C.O.P in Smart mode
8.5
7.7
7.5
8.0
7.6
C.O.P
15.5~7.5
16.0~6.6
15.5~6..5
16.5~7.0
16.3~6.5
C.O.P at 50% speed
12.0
11.5
11.5
11.6
11.5
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
in Smart mode
7.5
9.5
12.0
15.0
18.5
Heating capacity (kW)
in Booster mode
9.0
11.5
14.5
18.0
22.0
C.O.P
in Smart mode
5.5
5.2
5.2
5.6
5.5
C.O.P
7.0~5.0
7.5~4.5
8.0~4.7
8.0~5.1
8.0~5.0
C.O.P at 50% speed
6.7
6.8
7.0
7.0
7.0
Performance Condition: Air 35°C, Water 28°C, Humidity 80%
Sound pressure at 1m dB(A)
38.6~46.9
42.0~47.7
42.9~50.8
40.8~51.2
43.3~51.9
Sound pressure of 50%
capacity at 1m dB(A)
41.3
43.7
44.5
44.4
46.4
Sound pressure at 10m
dB(A)
18.6~26.9
22.0~27.7
22.9~30.8
20.8~31.2
23.3~31.9
Power supply
230V/1 Ph/50Hz
Rated input power(kW) at
air 15°C
0.22~1.8
0.26~2.56
0.31~3.08
0.38~3.53
0.46~4.4
Rated input current(A) at air
15°C
0.96~7.82
1.14~11.3
1.35~13.4
1.65~15.3
2.01~19.1
Advised water flux (m³/h)
3~4
4~6
6.5~8.5
8~10
10~12
Water pipe in-out Spec
(mm)
50
Net Dimension Lx WxH
(mm)
893×432×
650
939×432×
650
995×432×
750
1125×429×
952
1074×539×
947
Net Weight (kg)
61
63
70
90
96
1. The values indicated are valid under ideal conditions: Pool covered with an isothermal cover, filtration
system running at least 15 hours a day.
2. Related parameters are subject to adjustment periodically for technical improvement without further .
Содержание Turbo Silence IXR36
Страница 76: ...Version C02Xr32 ...