12
FOR INSTALLERS AND PROFESSIONALS
NOTE:
Must be hard wired, no plug allowed (In Australia, IPH15~IPH30 has plug for optional).
For your safe use in winter, it’s strongly recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
3. Options for protecting devices and cable specification
MODEL
IPH15
IPH20
IPH25
IPH30
IPH35
IPH45
IPH55
IPH70
IPH70T
IPH100T
Breaker
Rated Current
A
9.0
9.0
10.5
13.0
13.5
16.0
21.0
24.0
9.0
12.0
Rated Residual
Action Current
mA
30
30
30
30
30
30
30
30
30
30
Fuse A
9.0
9.0
10.5
13.0
13.5
16.0
21.0
24.0
9.0
12.0
Power Cord
(
mm
2
)
3×1.5
3×1.5
3×2.5
3×2.5
3×2.5
3×2.5
3×4
3×6
5×2.5
5×2.5
Signal cable
(
mm
2
)
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
3×0.5
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is
>
10m, wire diameter must be
increased. The signal cable can be extended to 50m at most.
2.3. Trial after installation
Please check all the wirings carefully before turning on the heat pump.
2.3.1
.
Inspection before use
➢
Check installation of the whole heat pump and the pipe connections according to the pipe
connecting drawing;
➢
Check the electric wiring according to the electrical wiring diagram and earthing connection;
➢
Make sure that the main power is well connected;
➢
Check if there is any obstacle in front of the air inlet and outlet of the heat pump
2.3.2
.
Trial
➢
The user is advised to start the water pump before the heat pump, and turn off the heat pump
before the water pump for long life circle.
➢
The user should start the water pump, and check for any leakage of water; Power on and press
the ON/OFF button of the heat pump, and set desired temperature in the thermostat.
➢
In order to protect the heat pump, the heat pump is equipped with start delay function. When
starting the heat pump, the fan will start to run in 3 minutes, in another 30 seconds, the
compressor will start to run.
➢
After pool heat pump starts up, check for any abnormal noise from the heat pump.
➢
Check the temperature setting.
Содержание IPH15
Страница 1: ...Thank you for choosing Fairland Full inverter heat pump INSTALLATION USER MANUAL ...
Страница 2: ......
Страница 18: ...15 FOR INSTALLERS AND PROFESSIONALS APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...
Страница 19: ...16 FOR INSTALLERS AND PROFESSIONALS APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...
Страница 20: ...17 FOR INSTALLERS AND PROFESSIONALS APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...