FOR INSTALLERS AND PROFESSIONALS 

 

3.FAILURE CODE 

 

NO 

Failure 

Code 

High pressure protection 

E1 

Low pressure protection 

E2 

Abnormal power supply voltage protection 

E5 

Exhaust high temp protection 

E8 

System high temp protection 

E9 

Air out high temp protection 

EA 

Environmental low temp protection 

Eb 

Controller failure 

P0 

Air inlet temperature sensor failure 

P1 

10 

Air outlet temperature sensor failure 

P2 

11 

Exhaust gas temp sensor failure 

P3 

12 

Gas return temp sensor failure 

P5 

13 

Evaporation coil temperature sensor failure 

P6 

14 

Ambient humidity sensor failure 

P7 

15 

Radiator temperature sensor failure 

P8 

16 

Current sensor failure 

P9 

17 

Restart memory failure 

PA 

18 

Compressor drive module or related wiring failure 

F1 

19 

PFC module failure 

F2 

20 

Compressor start failure 

F3 

21 

Compressor running failure 

F4 

22 

Inverter board over current protection 

F5 

23 

Inverter board overheat protection 

F6 

24 

Over current protection 

F7 

25 

Radiator high temperature protection 

F8 

26 

DC fan fault 

F9 

27 

PFC module over current protection 

FA 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание IDHR120

Страница 1: ...R32 Full inverter Dehumidifier INSTALLATION USER MANUAL...

Страница 2: ......

Страница 3: ...lation and Maintenance 7 1 1 Notice before installation 7 1 2 Instruction 10 1 3 Trail after Installation 15 1 4 Daily Maintenance Notice 15 2 TROUBLE SHOTTING FOR COMMON FAULTS 16 3 FAILURE CODE 17 P...

Страница 4: ...1...

Страница 5: ...1 FOR USER 1 GENERAL INFORMATION 1 1 Name of Parts No Name 1 Controller 2 Feet 3 Air Outlet 4 Air Inlet on the bottom 5 Hanging Strip on Wall 6 Pad...

Страница 6: ...2 FOR USER 1 2 Spare Part Lists Padx3 Feetx4 Drain pipe x1 2m Hanging Stripx1 Manual 1 3 Dimension IDHR60 IDHR96 IDHR120 A B C D E H Model Dimension Unit mm...

Страница 7: ...ehumidifier with optional electric heater press the button for 3 seconds to select the mode Heating Dehumidification Heating Dehumidification Timer Press to set the time to switch on and off Up and Do...

Страница 8: ...e setting range is 18 35 C The default is 26 C C Under the heating dehumidifying mode press the for the first time the humidity number flashes press or to set the desired humidity Automatically confir...

Страница 9: ...u can adjust the minute setting by pressing or and press the the will keep lighted the Timer OFF setting completed If you haven t pressed or to adjust the time time setting failed then withdrawal auto...

Страница 10: ...ent A Air 30 RH 80 0 48 3 17 0 74 4 30 0 96 5 91 Power supply 230V 1Ph 50Hz Sound pressure at 1 m dB A 35 3 45 6 35 6 46 1 35 9 46 4 Air flow m h 600 800 1000 Net dimension mm 850 291 850 1120 291 855...

Страница 11: ...effect 1 1 1 When storing or moving the equipment it should be at the upright position 1 1 2 The equipment is a general dehumidification product NEVER use it for other flammable and turbid gases 1 1...

Страница 12: ...se a fire may occur 1 1 7 If any abnormal conditions such as abnormal noise odor smoke leakage etc are found the power should be cut off immediately and contact the local dealer and do not repair the...

Страница 13: ...main power switch otherwise the lightening might damage the unit 1 1 10 Do not wash the equipment directly with water 1 1 11 Do not use for special purposes such as the preservation of fine arts or ac...

Страница 14: ...roof 3 Please ensure that the dehumidifier and the swimming pool are kept at a distance of 200cm or more Do not place objects which block the airflow near the air inlet or air outlet Do not set any ob...

Страница 15: ...it in the clockwise direction do not flip the equipment to install A Power Cord B Drain Outlet Connected with drain pipes 2 Connect the drain pipe and connect the power cord according to the cable dia...

Страница 16: ...12 FOR INSTALLERS AND PROFESSIONALS 2 Place the pad on the wall mounting platform behind the equipment 3 Hang the hanging strip on the back of the equipment on the bracket...

Страница 17: ...fter hanging the bracket gently put the equipment until the pad of the bottom rests against the wall 4 Connect the drain pipe and connect the power cord according to the wiring diagram A Power cord B...

Страница 18: ...devices leakage operating current 30mA 5 The layout of power cable and signal cable should be orderly and not affecting each other considering the environmental condition ambient temperature direct su...

Страница 19: ...1 3 2 Trail The user should open the power switch firstly then connect the power To protect the dehumidifier it is equipped with start delay function When starting the dehumidifier the fan will first...

Страница 20: ...ning but insufficient heating Evaporator blocked Remove the obstacles Air outlet blocked Remove the obstacles 3 minutes start delay Wait patiently Display normal but no dehumidification The set humidi...

Страница 21: ...Exhaust gas temp sensor failure P3 12 Gas return temp sensor failure P5 13 Evaporation coil temperature sensor failure P6 14 Ambient humidity sensor failure P7 15 Radiator temperature sensor failure...

Страница 22: ......

Страница 23: ...Version C00IDr32...

Отзывы: