Fairford SDF-02 Скачать руководство пользователя страница 1

1

SDF Digital

Star/Delta Replacement
Soft Starters

FAIRFORD ELECTRONICS

SDF-02

11kW @ 400V    22Amp

SDF-04

15kW @ 400V    29Amp

SDF-06

22kW @ 400V    41Amp

SDF-08

30kW @ 400V    55Amp

SDF-12

37kW @ 400V    66Amp

SDF-14

45kW @ 400V    80Amp

SDF-16

55kW @ 400V    97Amp

SDF-22

  75kW @ 400V   132Amp

SDF-24

  90kW @ 400V   160Amp

SDF-26

110kW @ 400V   195Amp

Installation Instructions

This device is suitable for use in industrial
environments. EN 55011/22 Class A
Das Gerät ist für den industriellen Einsatz
geeignet  EN 55011/22 Klasse A.
L’appareil a été conçu pour l’emploi en milieu
industriel  EN 55011/22 classe A.
L’apparecchio è adatto per uso in ambienti
industriali  EN 55011/22 Classe A.
El aparato es adecuado para uso en ambiente
industrial  EN 55011/22 clase A.

Electric shock risk. Danger

Only skilled or instructed persons may carry
out the following operations.

Lebensgefahr durch elektrischen Strom!

Nur Elektrofachkräfte und elektrotechnisch unterwiesene
Personen dürfen die im Folgenden beschriebenen
Arbeiten ausführen.

Tension électrique dangereuse !

Seules les personnes qualifées et averties doivent
exécuter les travaux ci-après.

Tensione elettrica: Pericolo di morte!

Solo persone abilitate e qualificate possono eseguire le
operazioni di seguito riportate.

¡Corriente eléctrica! ¡Peligro de muerte!

El trabajo a continuación descrito debe ser realizado
por personas cualificadas y advertidas.

Содержание SDF-02

Страница 1: ...ecchio adatto per uso in ambienti industriali EN 55011 22 Classe A El aparato es adecuado para uso en ambiente industrial EN 55011 22 clase A Electric shock risk Danger Only skilled or instructed pers...

Страница 2: ...13 2 0 0 8 x 4 1L1 3L2 5L3 2T1 4T2 6T3 mm2 AWG mm Nm mm 35 1 17 3 0 1 2 x 6 5 Mountings suitable for M6 160mm x 125mm centres M6 8 Nm M6 8 Nm Dimensions Abmessungen Dimensioni Dimensiones Power cable...

Страница 3: ...en Dimensioni Dimensiones A1 A2 S0 S1 13 14 23 24 mm AWG mm Nm mm 2 1 x 0 75 2 5 18 12 6 0 8 0 5 x 3 5 2 x 0 75 1 18 16 11 0 8 0 5 x 3 5 A1 A2 S0 S1 13 14 23 24 Control supply 24VDC Start stop 24VDC 1...

Страница 4: ...level Bei Mehrleiteranschluss darf maximal ein DIN Normgr en Sprung zwischen den verwendeten Leitern liegen En cas de raccordement de plusieurs conducteurs il faut 1 cartement normalis max entre les...

Страница 5: ...Semiconductor fuse for type 2 coordination in addition to Q1 Halbleitersicherung f r Zuordnungsart 2 zus tzlich zu Q1 Per avere la protezione del semiconduttore in coordinamento di tipo 2 necessario...

Страница 6: ...70 for smaller motors Soft Stop time 0 default range 0 S to 12 S Soft Start time 5 default range 0 5 S to 12S LED green LED gr n DEL vert LED verde LED verde 1 Ready for operation Betriebsbereit Pr t...

Страница 7: ...n the scope of the EU Directives the SDF soft starters and their accessories may be commissioned only provided it is established that the machine fulfils the protective requirements of Machine Directi...

Страница 8: ...110kW 160A 90kW Operational Voltage Ue 230 460 VAC rms 3 Phase 15 10 Rated Frequency 50 60Hz 2Hz Form Designation Form 1 Index Rating Standard AC53a 3 5 99 10 Class 10A AC53a 3 12 99 10 Control Supply...

Отзывы: