HFE-2 Soft Start User Manual 
MAN-HFE-002. Version 01. 18/08/2016 

 

 

 

5

 

 

 

 

Rating Table 

Load 

Amps 

(Ie) 

Utilisation 

Category 

Start 

Duty 

Up to  

Starts/Hr 

Current 

(Amps) 

Time 

(Secs) 

30 

AC53a 

90 

99% 

60 

 
 

IEC Rating Index 
 

 

 

 

 

Specifications 

Pedestal Voltage: 
Start Time: 
Terminations: 
 
Ambient Temperature: 
Enclosure: 
Rated Operational Voltage: 
Recommended cut–out device: 
Rated insulation voltage: 
Rated impulse withstand voltage: 
Short circuit co–ordination: 
Fuse Type: 
Form designation: 
Pollution Degree: 
EMC Emissions: 
EMC Immunity: 
Design standards:  

Fixed at ~15%. 
Continuously variable from 0.5S -5S. 
Cage clamp terminals suitable for 1.50mm2 (12awg) 
to 25mm

2

 (4 awg) solid or stranded wire 

0°C to 40°C without derating. 
IP20 with standard cover: 
Ue: 110 to 230V ac (–15% +10%), 50/60Hz 
32A rated MCB, Trip Characteristic “C“. Form 1 
Ui: 250V 
Uimp: 4kV (1.2 / 50μs) 
Type 1 , Iq: 5kA when protected by recommended Fuse 
Bussman 170M3113 or Ferraz 6,6 URD 30 D098A 0125 
Form 1 

EN 55011 Environment Class B 
EN 60947-4-2 
IEC 60947–4–2: “AC Semiconductor Motor Controllers and 
Starters”. 

 
 

 

Ratings and Specifications 
 

Duty Cycle (F-S)

 

99-10 = 99% duty cycle - 60  cycles/hr

 

Rated Operational Current (Ie)

 

30A = Rated Operational Current 

 

Overload Current Profile (X-Tx)

 

4-3 = 3 times rated current (Ie) for 3s

 

Utilization Category

 

AC-53a = controller semiconductors provide squirrel-cage motor Start, Run, and Stop  control

 

     30A    :  AC-53a: 3 

 3 : 99-60

 

Содержание HFE-2

Страница 1: ...Innovation in soft start technology HFE 2 USER MANUAL MAN HFE 002 Version 01...

Страница 2: ...nquiries about copyright of Fairford Electronics deliverables should be made to Fairford Electronics Ltd If by permission of the copyright owner any part of this document is quoted then a statement sp...

Страница 3: ...oltage which could result in personal injury or death Warning Caution Indicates a potential hazard Any instructions that follow this symbol should be obeyed to avoid possible damage to the equipment a...

Страница 4: ...Three off 21mm holes for cable glands The system may be configured to allow for auto restart controlled from contacts on the motor side of the unit Users and operators must always take all necessary p...

Страница 5: ...of the unit See Specifications section for recommended fuse type and cut out device Set the ramp time potentiometer to midway to approx 2 seconds and start the system If the motor turns instantly when...

Страница 6: ...erminals suitable for 1 50mm2 12awg to 25mm2 4 awg solid or stranded wire 0 C to 40 C without derating IP20 with standard cover Ue 110 to 230V ac 15 10 50 60Hz 32A rated MCB Trip Characteristic C Form...

Страница 7: ...HFE 2 Soft Start User Manual MAN HFE 002 Version 01 18 08 2016 6 Notes...

Страница 8: ...HFE 2 Soft Start User Manual MAN HFE 002 Version 01 18 08 2016 7 Fairford Electronics Ltd Bristow House Gillard Way Ivybridge PL21 9GG UK www fairford com...

Отзывы: