© 2011 Fairchild Semiconductor Corporation
11
FEBFSB127H_T001 • Rev. 1.0.0
5.10.
Short-Circuit Protection
5.10.1.
Test Condition
In the event of a short circuit on any DC output, the power supply should be protected
from damage.
5.10.2.
Test Result
90V / 60Hz
264V / 50Hz
Minimum Load
PASS
PASS
Maximum Load
PASS
PASS
5.10.3.
Measured Waveforms
Figure 14. 90V
AC
/60Hz, Output Short
(Ch1: Drain, Ch2: V
DD
, Ch3: FB)
Figure 15. 264V
AC
/50Hz Output Short
(Ch1: Drain, Ch2: V
DD
, Ch3: FB)
5.11.
X-Cap Discharge
5.11.1.
Test Condition
The voltage will have decayed to 37% of its original value in one second after the AC
input plug is disconnected.
5.11.2.
Measured Waveforms
Figure 16. 264V
AC
/50Hz, No Load, X-Cap=0.47
μ
F, R
HV
=200k
Ω