9.8.
AC Cycle Drop
Test Condition:
After AC input drop 0.5 cycle, check system to ensure that no damage occurred and
behavior is correct. If the AC drop time increases to 1 cycle, the Vbulk will drop too
much to make the 12 V V
O
also drop. So, it’s also about min. frequency of controller.
Test Results:
115 V
0 V
115 V
230 V
0 V
230 V
100% Load
100% Load
Pass
Pass
Ch1: 12Vo,
Ch2: Iin
,
Ch3: VAC
,
Ch4: Vbulk
115 V
0 V
115 V, Max. Load
230 V
0 V
230 V, Max. Load
Figure 21.
Test Waveform of AC Cycle Drop
9.9.
AC Transient
Test Condition:
AC Transient in 115
V
80 V
115 V and 230 V
160 V
230 V conditions, check
system to ensure that no damage occurred and behavior is correct.
Test Results:
115 V
80 V
115 V
230 V
160 V
230 V
100% Load
100% Load
Pass
Pass
Ch1:
12V
O
,
Ch2:
Iin
, Ch3:
VAC
, Ch4:
Vbulk
115 V
80V
115 V, Max. Load
230 V
160 V
230 V, Max. Load
Figure 22.
Test Waveform of AC Transient