To clean the Model 1600A, use the following steps:

1.

2.

3.

4.

5.

If the standard maintenance procedure
does not correct the problem, install the
appropriate service kit.

Shut off system pressure to the regulator to
prevent air from escaping.  It is not necessary to
remove the regulator from the air line.

Remove the four Screws and Washers (between
ports) from the bottom of unit.  For more informa-
tion, see Figure 2.

Remove the Inner Valve Assembly.  For more
information, see Figure 2.

Wash the Inner Valve Assembly with a solvent.
Exercise care to prevent damage to diaphragms
and valve facings.  

Avoid solvents such as

acetone, carbon tetrachloride and trichlor-
ethylene.

Replace the assembly carefully.  Ensure that the
Vent in the exterior part of the Inner Valve
Assembly and the Vent in the Bonnet are clear.
For more information, see Figure 2.

MAINTENANCE

Troubleshooting

Figure  2.  

Model 1600A Exploded Drawing

Source

Problem

•  If contaminated,
   clean the source
   and Body.

•  If damaged, install
   the service kit.

Solution

High
Bleed

Leakage

Tighten the
Bonnet Screw.

•  Relief Valve
•  Supply Valve
•  Supply Seat

•  Diaphragm
   Assembly

Bonnet
Screws

NOTE:

Standard

• EA-19552-1