IS-100010BP

Litho  in  USA

03/2007

To clean the Model 10BP,
use the following steps:

1. Shut off system pressure to the

regulator to prevent air from escaping.  It
is not necessary to remove the regulator
from the air line.

2. Turn the Knob Assembly counterclock-

wise to relieve the compression on the
Range Spring.

3. Remove the six Screws from the Bonnet

Assembly. For more information, see

Figure 2

.

4. Remove the Bonnet, Spring and

Diaphragm Assembly.  For more
information, see 

Figure 2.

5. Wash the Diaphragm Assembly with a

solvent.  Exercise care to prevent dam
age to diaphragms and valve facings.

Avoid solvents such as acetone,
carbon tetrachloride and
trichlorethylene.

6. Carefully reassemble the unit.  Ensure

that the Vent in the  Bonnet is clear.  For
more information, see 

Figure 2.

MAINTENANCE

Figure  2.  

Model 10BP Exploded Drawing

If the standard maintenance procedure does
not correct the problem, install the appro-
priate service kit.

Service Kit

Range

• 12127-1

2-150 psig

• 12127-2

300 psig

• 15743

400 psig

NOTE:

Troubleshooting

Source

Problem

Solution

Difficult

to

adjust

Leakage

Tighten the screws.

•  Adjust the screw
   and ball.

• Check the
   lubrication.

•  Adjusting Screw
  and Ball

• Seal ring
  lubrication

•  Body Screws
•  Diaphragm