Pic. 11
Control panel
Key 1: pressed once allows access to the water temperature set. If key 1 is kept pressed it indicates the
pellet loading speed.
Key 2: pressed once allows access to the room temperature set. If key 2 is kept pressed it indicates the
flue gas temperature and the rpm of the smoke extraction motor.
Keys 1 and 2: in set temperature mode increase or decrease the value of the thermostat from minimum
07 ° C to max 40 ° C, in programming mode they change the parameters.
Key 3: allows access to the user and technical parameters menu.
Key 4: (ON-OFF) on and off, release from eventual alarms and exit from programming.
Key 5: once pressed it allows to set the fan speed modifiable with keys 1 and 2 (AIR models only),
keeping the button pressed the system water pressure is displayed in Bar.
Key 6: pressed once allows to set the power of the stove.
Keys 5 and 6: in the programming mode, the menus are scrolled.
Display: shows the board status during start-up. during work, it shows the heat power and the room
temperature. While modifying parameters, it shows the value of the parameter being modified.
Display symbols
The figure describes the meaning of the status signallers on the left of the display.
Activation of one of the segments in the status area on the display signals activation of the
corresponding device according to the following list.
They are, in order:
1.
Clock thermostat;
2.
Glow plug;
3.
Cochlea;
4.
Fumes extractor;
5.
Heat exchanger;
6.
Circulation water pump;
7.
Alarm.
Structure of Menu
The available menu is divided into 8 entries:
Menu 01
SET CLOCK;
Menu 02
SET CHRONO;
Menu 03
SELECT LANGUAGE;
Menu 04
MODE STAND-BY;
Menu 05
MODE BUZZER;
Menu 06
INITIAL LOAD;
Menu 07
STATE STOVE;
Menu 08
SETTINGS TECHNIC.