40
Failure modes on display of electronic chamber thermostat:
If the following message appears on the electronic thermostat display:
_ _ 0
Thermocouple or chamber probe cut off.
-Check connection between thermocouple and electronic thermostat
-Change chamber probe
_ _ 1
NTC open.
-Change electronic thermostat.
_ _ 2
Selector potentiometer 30-270ºC broken.
- Change electronic thermostat.
_ _ 3
Selector potentiometer 100ºC broken.
- Change electronic thermostat.
Failure modes in core probe thermostat display:
If the following message appears on the electronic thermostat display:
“_ _ _” Short-circuited core probe.
“EEE” Core probe cut or not connected.
Содержание HVG-10/11
Страница 1: ...TECHNICAL MANUAL GAS OVENS HVG and HCG NOVEMBER 2001 FAGOR Industrial S Coop...
Страница 3: ...3 1 MODELS AND DIMENSIONS fig 1 fig 2...
Страница 4: ...4 fig 3...
Страница 5: ...5 fig 4 fig 5...
Страница 25: ...25 HVG SIDE VIEW OF ELECTRICAL COMPONENTS fig 38 Gas intake Electrical wiring connection inlet...
Страница 26: ...26 HVG REAR VIEW fig 39 Soft water connection...
Страница 28: ...28...
Страница 29: ...29 fig 40...
Страница 30: ...30 fig 41...
Страница 31: ...31 fig 42...
Страница 32: ...32 fig 43...
Страница 56: ......
Страница 57: ...57...