44
Adjusting amount of steam in Mixed and Regeneration Mode.
The oven is adjusted for an optimum amount of steam, but if for any reason
the user wants more, do the following:
1. Locate the energy regulator
RE 1
. this is regulated approximately to give
15 seconds of steam and 15 seconds without steam. Both in Mixed and
Regeneration.
2.Turn clockwise to increase amount of steam
.
Regulating steam in:
Regeneration and mixed mode
fig 49
fig 50
fig 51
Adjusting I K-type core probe thermostat K.(red case)
K-type thermocouple (Nickel-chrome/Nickel- aluminium
) “Cr” probe
type parameter in PSE
-Simultaneously activate core probe selector (1) and SET (2), holding SET
down for approximately 4 seconds until “d1” appears on the display (3).(fig
53)
- With DOWN (5) move parameters until (3) “PSE” appears on display.
(fig 54)
- With “PSE” on display press SET again and hold down.
Position of
RE 2
Energy
Regulator
Pin
To obtain more steam, turn the
pin clockwise
RE1
Содержание HCG-10/11
Страница 1: ...TECHNICAL MANUAL GAS OVENS HVG and HCG NOVEMBER 2001 FAGOR Industrial S Coop...
Страница 3: ...3 1 MODELS AND DIMENSIONS fig 1 fig 2...
Страница 4: ...4 fig 3...
Страница 5: ...5 fig 4 fig 5...
Страница 25: ...25 HVG SIDE VIEW OF ELECTRICAL COMPONENTS fig 38 Gas intake Electrical wiring connection inlet...
Страница 26: ...26 HVG REAR VIEW fig 39 Soft water connection...
Страница 28: ...28...
Страница 29: ...29 fig 40...
Страница 30: ...30 fig 41...
Страница 31: ...31 fig 42...
Страница 32: ...32 fig 43...
Страница 56: ......
Страница 57: ...57...