36
to observe this requirement.
•
An easily accessible differential protection device of suitable capacity should be
installed next to the appliance. The manufacturer will not be held liable for damage
originated by failure to observe this requirement.
•
If any faults are observed during the installation, the supplier should be notified
immediately.
•
Before replacing the switchboard cover, fasten the electric supply cable
tightly to the stuffing box.
The manufacturer will not be held liable for any personal or material damage to the
machine resulting from incorrect
installation or failure to comply with the manufacturer’s
specifications.
4.5
Gas connection
An AUTHORISED TECHNICIAN should always carry out the gas connection of the appliance.
•
The general installation must have a mains tap and a pressure regulator and it is
also advisable to install a shut-off cock on each individual appliance.
•
A pipe of at least Ø 12 x 10 mm should be used for the gas connection, together
with a ¾” nut to connect to the pasta cooker.
4.6
Conversion to other types of gas
If the appliance is prepared for a different type of gas to the one available in the installation, you
should proceed as follows:
1.
Disconnect the gas supply to the appliance if connected (Any change to the conditions of the
gas circuit must be carried out by an AUTHORISED TECHNICIAN)
2.
Burner conversión:
a.
Open the door to access the burner.
b.
Remove the burner injectors and replace with the correct model according to the gas
to be used (Table 3).
c.
Set the air control to position H (table 3) depending on the gas to be used.
3.
Pilot conversion
a.
Open the door to access the pilot light.
b.
Undo the pilot unit.
c.
Remove the pilot injectors and replace with the correct model according to the gas
to be used (Table 3).
d.
Replace the pilot unit.
4.
After adapting the appliance to another type of gas or to another pressure, other than that for
which it had been previously set, the old instructions should be replaced with the instructions
for the new settings, to enable unambiguous identification of the state of the appliance after
modification.
Burner
Содержание CP-G7126
Страница 7: ...7 CP G7140 A Entrada de Agua Water Inlet G Entrada de Gas Gas Inlet D Desag e Drainage...
Страница 8: ...8 CP G7240 A Entrada de Agua Water Inlet G Entrada de Gas Gas Inlet D Desag e Drainage...
Страница 91: ...91...