ENGLISH
CONCEPT USE AND MAINTENANCE MANUAL
25
DELTA FUNCTION
Difference between the core temperature and the oven temperature.
The oven temperature is always 50ºC higher than the temperature recorded by the core
probe.
Select by pressing button 17 and with the
delta
display lit.
Probe temp + 50ºC
Turn control 13 to select the required
core temperature (for example 70ºC)
displayed in window 12.
Insert spike probe in food (for
example 15ºC) displayed in window
11.
The oven will heat up to 15ºC+50ºC
65ºC and as the temperature of
the core rises, the oven temperature
will increase, always maintaining a
difference of +50ºC.
When the core temperature reaches
the
selected
70ºC,
the
oven
temperature is 120ºC and an alarm
will be heard.
In this function, control 10 (for
selecting the oven temperature) is
inoperative.
In steam mode, set at 99ºC, the
adjustment range is only from 0 to
49ºC.
In the convection and mixed modes,
the adjustment range is from 0 to
99ºC.
True oven temp.
Function cancelled
Selected core
temp.
True core temp
Core probe temp.
selection
Delta function
display