Freeze Protecting Your System
The installations most prone to freeze damage include systems that have collectors below the pool
water level and systems installed in hard freeze locations. All systems, when shut down for the win-
ter, must be checked to ensure that they are completely drained.
It is strongly suggested to perform a winterization and spring tune-up for your Connected Tube
CT
system annually so that you don’t void the warranty.
If you choose to winterize your system yourself, follow these steps:
1. Ensure that the pump is not running.
3. Open manual drain valves if equipped.
4. Remove Vacuum Relief Valve and end caps at the lowest collector and store for winter
5. Let the system drain completely for a few minutes.
6. Close the solar isolation valves.
7. Ensure the diverter valve is set to bypass the Connected Tube
CT
System and that the automation
equipment is properly decommissioned for winter use.
8. Ensure that the diverter valve is turned to the thermal off position and turn on the pool equip-
ment. Let the system run for at least 5 minutes while checking to make sure no water is coming
out of the end cap area of the collectors.
It is strongly suggested to perform a winterization and spring tune-up for your Connected
Tube
CT
system annually so that you don’t void the warranty.
If you choose to start up the system yourself, please follow the steps bellow:
1. Ensure the pump is not running
2. Close solar drain valves if included
3. Reinstall end caps and vacuum relief valve
4. Open the solar isolation valves
5. Turn on the pool pump and recommission the solar automation system
6. Inspect the system for any leaking and address as needed
7. Watch the pool inlet to ensure that all air is purged and that no champagne bubbles remain. If
bubbles remain, address the issue
8. Run through the automation system and ensure the system is operating as intended
9. Address anything that may need service or attention as necessary
10.
The pool pump, filter, sweep, solar system and any other applicable equipment can now be used for
the summer
System Start-up After Freezing Conditions