page 13
XE
Photocells:
1
DIP-SWITCH-A N° 1:
ON
: stop in Opening and reverse in
Closing once cleared from obstacle
OFF
: no stop in opening, reverse on closing in
case of obstacle
Radio Contact:
(step-by-step mode)
connecting any NO contact across the two
terminals generates, with each impulse:
- Opening only:
- inversion of direction with each impulse
- Step-by-step: Open-Stop-Close-Stop
- During opening no new command is
accepted. During dwell or closing, each new
command stops and reverses travel
direction.
ON
:
no stop and no reversing in opening
OFF
:
during opening always stop and reverse
2
ON
:
Step-by-step with intermediate stop
OFF
:
reverse movement by every radio impulse
5
DIP-SWITCH-A N°2 and N°5:
All NC contacts of
safety accessories
such as Photocells
(receivers) must be
connected in series
with terminals 1 and 2
Accessory
Electrical connections
NC
NC
1 2
3
7
L3 ON
= no obstacle. It switches off in case
of obstacle
L7 OFF=
no RADIO contact, turns on with
every radio contact impulse
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12
DIP-SWITCH - A
meccanica
FADINI
FOR
SLIDING GATES WITH LIMIT SWITCHES
:
position Dip Switch B No1= ON
Safety edge:
1 2
NC contact for safety edge to allow travel reversing for a short
bit in both cycles and gate stopping: with
DIP-SWITCH-A N°8 and N°9:
Increase time during inversion
No increase of inversion time
8
Inversion of direction with safety edge
No inversion of direction
9
Limit switches:
if the limit switches
then bridge inputs 8 - 9 - 10
L8 ON
=
off when gate closed
L9 ON
=
off with gate open
1 2 3 4
ON
OFF
DIP-SWITCH - B
L2
= no obstacle detected, turns off in
case of obstacle
2 3 4
1
ON
OFF
DIP-SWITCH - B
Dip-Switches and LED signals of the various functions
12 13
GB
XE
UNIVERSAL ELECTRONIC CONTROL BOXES
230V 50/60Hz SINGLE-PHASE
No function
= see SAFETY EDGE connections
= see SAFETY EDGE connections
Flashing light off during pause
Closes during Opening and during pause after passage on the
Photocells
mode
Deadman mode
DSA photocell transmitter control if connected to dedicated terminals
Photocells stop during opening
Radio does not reverse during opening
Automatic closure
Pre-flashing operational
Step-by-step radio
Pedestrian service
max. load:
n°1 radio receiver
n°2 pairs photocells
Key-operated
switch:
3 4 5 6
NC
L4 OFF=
no OPEN contact, turns on with
every open impulse
L5 OFF=
no CLOSE contact, turns on with
every close impulse
NO and NC contacts to connect to
the respective terminals on the
selector switches or the push-button
panel.
All possible configurations are
attached to the related control
accessories.
L6 ON=
STOP contact closed, turns off with
every stop impulse
8 9 10
X