background image

6

4138

Drwg. No.

LOW VOLTAGE ELECTRICAL CONNECTIONS

®

GB

SINGLE-/THREE-PHASE FOR SLIDING GATE OPERATORS MEC 200

PLUS

70/3

11 12

20

22

21

Safety Switch

Radio Power Supply

1

2

16 17

Push Button Switch:

Photocell:

18 19

PHOTOCELL
CONTACT

POWER SUPPLY 24V

LIGHT

+24V

16 17

1

DIP-SWITCH 1:

ON: Photocells stop gate while opening,
       reverse it on closing once obstacle is
       removed

OFF: Photocells do not stop gate while
        opening, reverse it on closing in
        case of an obstacle

Limit switch:

15

COMMON

13 14

LIMIT SWITCH

CLOSE

LIMIT SWITCH

OPEN

Radio Contact:

10

9

COMMON

RADIO

CONT

ACT

- Open/Close (Standard)
- Travel reversing on pulsing
- Step by step

2

5

ON: Step by step. Stop in between

OFF: Standard operating mode

ON: Gate is not reversed while opening

OFF: Any pulse reverses the gate

DIP-SWITCH 2 and 5 (NEVER set BOTH of them to ON at the same time):

STOP

COMMON

OPEN

CLOSE

3

4

5

INDICATION
LAMP OPEN

48V max 3A

INDICATION

LAMP CLOSE

48V max 3A

7

8

6

24V 3W Indication Light:

Light ON = Open gate
Light OFF = Closed gate
Flashing (fast) 0.5s = Closing gate
Flashing (normally) 1s = Opening gate
Flashing (slowly) 2s = gate is stopped

Electric lock:

Set the T4 Trimmer Time to the lowest value
The electric lock is excited for 2 seconds

Connect a 24VAC Modular Relay
(T4 Trimmer Time from 2s to 255s)
to operate a 230V lamp

Courtesy light:

POWER SUPPLY 24V

Отзывы: