QHC18M  18Kw Heater Controller   Din Rail & connections

 

 

   

Distribution Box

P/No. QHDB-1824

  

 

Terminals 1 – O/P1

Terminals 2 – O/P2

Terminals 3 – O/P3

Terminals N – N out

Terminals E – Earth

    

5) When all connections are complete and connected correctly, check once again that the wiring is correct 

as per 3) & 4). Then replace the service hatch cover and tighten the fixing screws.

6) Turn ON or reconnect the Main Power to the controller. The red neon lamp on the front panel will 

illuminate to indicate that the unit is 

LIVE

.  

7) There are auxiliary devices such as mains operated PIR motion detectors & timer (lag) switches. These 

can be connected to terminals #15 – 17.   External push button switches which are voltage clean or free 
can be connected to terminals #18 – 20. 

8) An optional auxiliary device QHVC-S external 3 zone variable control can be connected to terminals 

#21 –  25.   Please contact the agent or distributor for auxiliary device instructions.
             

    

Important only a qualified electrician should install this device.

                  