P&G CONTROLLER COMMON ERROR CODES

Diagnostic Code Cause

Correction

1501

Parking brake is released or the parking brake coil 
circuit is open

Check to assure the parking brake is not manually 
released.

1507

Parking Brake Over Current

Parking brake coil is internally shorted or there is a 
problem with the wiring to the brake. 

2C00-2C02

Battery voltage is low     

Charge the batteries with OEM supplied charger. 

2F01

Throttle is depressed during power on or a fault with 
the throttle system

Turn the machine off, assure that the throttle 
button(s) or throttle pedal are not depressed.  Turn 
the machine back on and  if the condition persists, 
seek technical support from  your local authorized 
RPS distributor.

3101

Brush / Vac Motor - Precharge Fault

This code can be caused by the scrub or vacuum 
motor(s) having moisture present or contaminated 
with debris.

3102

Traction Motor - Precharge Fault

This code can be caused by the traction motor 
having moisture present or being contaminated. 

7600

Brush Motor Circuit Open

The controller is not seeing continuity on the brush 
motor circuit.  This can be caused by the wiring to 
the scrub brush motor(s), corroded connections or a 
faulty motor.

7601-7603

Brush Motor Circuit Over Current

The brush motor output is exceeding its limit.  With 
the scrubber turned off, check for entrapped debris 
around the brush driver(s) and assure the brushes 
turn freely.

7700

Vacuum Motor Circuit Open 

The controller is not seeing continuity on the 
vacuum motor circuit.  This can be caused by the 
wiring to the scrub brush motor(s), corroded 
connections or a faulty motor.

7701-7703

Vacuum Motor Circuit Over Current

The vacuum motor output is exceeding its limit. This 
can be caused by a faulty vacuum motor(s) or 
damaged vacuum motor wiring. 

1E03

Charger / Seat Switch – Charger is plugged in or 
operator is not on the seat of ride on equipment. 

On board charger is plugged into the wall outlet.  Off 
board charger is plugged into charging port. The 
switch at the charger plug for an external charger is 
out of adjustment. (Operator is not present on seat 
GTR and EX machines Prior to Serial Number 100xxx)

7500

LCD Communication Error

The LCD lost communication to the controller.  Check 
the 6 wire harness between the LCD module and it's 
connections.

7801-7802

Traction Motor Over Current      

The traction motor output is exceeding its limit.  
Check to assure the parking brake is releasing when 
the throttle is engaged.  Assure all wheels that 
contact the floor turn freely.

7804

Boost Mode

The code 7804 indicate the controller is in Boost 
Mode and considered normal under hard 
acceleration or when climbing a hill.

7900

Emergency Stop Activated           

The emergency stop is activated. If the machine is 
not equipped with an emergency stop switch 
typically the LCD module has failed. 

Below are common diagnostic codes and some typical causes / remedies. If the information provided in the "Correction" section does 

not cure the code, seek technical support from your local authorized RPS Corporation distributor. 

Содержание GTR

Страница 1: ...53404 USA 800 634 4060 001 262 681 3583 V18 234 2018 RPS Corporation FC GTR OP EN Operating Instructions EN Read these Instructions before using the machine Read these Safety Messages before using th...

Страница 2: ...excellent performance but the best results will be obtained at the most minimum costs if The machine is regularly maintained per the Authorized Local Distributor The machine is operated with reasonab...

Страница 3: ...nal 17 RPM Mode Switch Optional 18 Battery Setup 19 Remove Squeegee 20 Adjust Squeegee 21 Remove From Charger 22 Transportation Forward 23 Transportation Reverse 24 Fill Solution Tank 25 Operation Scr...

Страница 4: ...rized to do so by your RPS Authorized Local Distributor Unless you have read and understood this Operator s Manual On surfaces with greater than an 2 3 49 grade On Loading Docks WHEN OPERATING THIS MA...

Страница 5: ...emove paint over or destroy warning decals If warning decals become damaged call 1 262 681 3583 for free replacements WARNING Dress safely Do not wear a neck tie scarf or any loose or dangling clothin...

Страница 6: ...USE ONLY THE OEM CHARGER PROVIDED WITH THE MA CHINE ALWAYS DISCONNECT THE BATTERY BEFORE SERVICING THE MACHINE REFER TO MANUAL OR CALL 011 262 681 3583 DANGER EXPLOSION RISK EXPLOSIVE HYDROGEN GAS FO...

Страница 7: ...ion flow is ON 6 VACUUM ON Indicates the Vacuum is ON 7 KEY SWITCH HOUR METER Indicates total hours the machine has had keyswitch ON 8 TRANSPORT HOUR METER Indicates total hours the drive system has b...

Страница 8: ...8 FC GTR OP EN 1 2 3 EMERGENCY STOP OPERATION CONTROLS 2 3 1...

Страница 9: ...FC GTR OP EN 9 4 5 6 7 8 9 10 4 5 6 7 8 OPERATION CONTROLS 9 10...

Страница 10: ...10 FC GTR OP EN 11 12 13 14 15 65 100 16 17 18 OPERATION CONTROLS 17 18 14 15 11 16 12 13...

Страница 11: ...ent in the Yellow Vac Box will drain when vacuum is off 21 VACUUM DISCHARGE Water passed through the Vacuum Motor will be visible in the reservoir and excess will flow from the blue hose Indicates ser...

Страница 12: ...12 FC GTR OP EN 25 SPRAY JET CONTROLS OPTIONAL 25...

Страница 13: ...FC GTR OP EN 13 SUDS CONTROLS OPTIONAL 250 1 0 5oz gal 4ml 1L Single Dose 125 1 1oz gal 8ml 1L Double Dose O OFF...

Страница 14: ...14 FC GTR OP EN ZERO3 CONTROLS OPTIONAL Turn regular solution OFF when using ZERO3 Aqueous Ozone 100 Yellow Green Lights ON O OFF 65 Green Light ON...

Страница 15: ...FC GTR OP EN 15 MANAGER LOCK OUTS OPTIONAL CONTROLLING MANAGER LOCK OUTS When the key is in the LOCKED position keys can be removed and Solution OR Down pressure cannot be adjusted UNLOCKED LOCKED...

Страница 16: ...16 FC GTR OP EN HEADLIGHTS WORK LIGHTS OPTIONAL OFF OFF HEADLIGHTS REAR WORK LIGHTS ON HEADLIGHTS REAR WORK LIGHTS ON HEADLIGHTS ON HEADLIGHTS ON...

Страница 17: ...FC GTR OP EN 17 SIDE BROOM SYSTEM OPTIONAL ON ON OFF OFF...

Страница 18: ...18 FC GTR OP EN RPM MODE SWITCH OPTIONAL RPM 100 100 80 80 100 RPM 80 RPM 100 RPM 80 RPM 100 RPM 80 RPM 100 RPM 80 RPM...

Страница 19: ...ric acid which causes burns to skin If battery acid contacts clothing or skin rinse the effected area with cold water immediately If battery acid gets on your face or in your eyes flush the area immed...

Страница 20: ...20 FC GTR OP EN REMOVE SQUEEGEE 1 OFF 3 2 4 A B B C...

Страница 21: ...FC GTR OP EN 21 ADJUST SQUEEGEE...

Страница 22: ...22 FC GTR OP EN REMOVE FROM CHARGER Please refer to OEM Charger Operating Instructions for more information 1 2...

Страница 23: ...FC GTR OP EN 23 2 TRANSPORTATION FORWARD ON 1 0 3 3mph 0 5 3 kph...

Страница 24: ...24 FC GTR OP EN ON TRANSPORTATION REVERSE 1 2 0 1 6mph 0 2 6 kph...

Страница 25: ...162 l 130 F 54 C 46 Gal 162 l 130 F 54 C 4 2 TO AVOID DAMAGE TO THIS MACHINE s 53 002 6 4 2 43 9 s 7 4 2 4 0 2 452 534 4 8 F 54 s 4 53 0 2 4 8452 REFER TO MANUAL OR CALL 011 262 681 3583 DANGER EXPLOS...

Страница 26: ...26 FC GTR OP EN OPERATION SCRUBBING ON 1 2 3...

Страница 27: ...FC GTR OP EN 27 DRAINING RECOVERY TANK WASTE WATER DRAINS ONLY WASTE WATER DRAINS ONLY 1 2 3 NOTICE Drain clean Solution dirty Recovery solution into APPROVED drains...

Страница 28: ...28 FC GTR OP EN DRAINING SOLUTION TANK WASTE WATER DRAINS ONLY WASTE WATER DRAINS ONLY 1 2 3 NOTICE Drain clean Solution dirty Recovery solution into APPROVED drains...

Страница 29: ...FC GTR OP EN 29 FLUSHING RECOVERY TANK 1 2...

Страница 30: ...30 FC GTR OP EN CLEAN DRAIN SAVER 1 2...

Страница 31: ...FC GTR OP EN 31 CLEAN CYLINDRICAL HOPPER 2 3 1...

Страница 32: ...32 FC GTR OP EN CLEAN VAC BOX SYSTEM 1 3 5 6 2 4...

Страница 33: ...FC GTR OP EN 33 REMOVE DISK BRUSHES 2 1 Replace brush when fibers reach 1 4 inch in length Rotate after 25 hrs...

Страница 34: ...34 FC GTR OP EN REMOVE CYLINDRICAL BRUSHES Rotate after 25 hrs 3 4 2 Replace brush when fibers reach 1 4 inch in length 1...

Страница 35: ...this machine on ramps or slopes Always park this machine on a level hard surface Do not operate this machine outdoors or on uneven surfaces WARNING Understand the dynamic braking system before you op...

Страница 36: ...tructions for more information 1 2 DANGER Explosive hydrogen gas forms when Batteries are charging An open flame or spark can cause this gas to explode Serious personal injury or property damage could...

Страница 37: ...ower OUT 36VDC 25A ST 36A HD Please refer to OEM Charger Operating Instructions for more information BATTERY CHARGERS Onboard AGM International Chargers AC Power 80 270VAC 50 60Hz DC Power OUT 36VDC 3...

Страница 38: ...ICE The in Disk Column Denotes Desk Pad Size 15 or 17 DISK PADS DISK LEVEL COLOR Super Black 422BB Very High Black Black 422B High Black Brown 422BR High Brown Green 422G Medium Green Blue 422BL Moder...

Страница 39: ...eegee 36 770L 36 770G 36 770U 36 7180 39 Squeegee 39 770L 39 770G 39 770U 39 7180 SQUEEGEE MATERIAL USED FOR LINATEX Provides best wear and tear resistance Not designed for use with harsh chemicals UR...

Страница 40: ...uum Motor Circuit Open The controller is not seeing continuity on the vacuum motor circuit This can be caused by the wiring to the scrub brush motor s corroded connections or a faulty motor 7701 7703...

Страница 41: ...BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK...