- 44 -
FC-RIDERS-v2-OP-EN v22.235
Error
Internal Label
Code
Type
Description
Action
Remedy
Brake fault
BRAKE_FAULT
26
hard
An illegal voltage has been read
from the brake feedback circuit
The machine is disabled
Alarm fault
ALARM_FAULT
27
soft
Auxilliary output 1 fault
AUX_1_FAULT
28
soft
Auxilliary output 2 fault
AUX_2_FAULT
29
soft
Auxilliary output 3 fault
AUX_3_FAULT
68
soft
Deck actuator idle
current over limit
BRU_DECK_NULL_ERROR
30
soft
An abnormally high idle current
has been detected in the deck
actuator motor
Brush, deck actuator and
water/suds are disabled
Transport motor stalled
TRACTION_STALLED_MOTOR
31
hard
An energized transport motor is
not rotating
Transport motor circuit
current over limit
LEFT_DRAIN_OV
32
hard
There is excessive current in the
transport motor drive circuit
Transport motor circuit
current over limit
RIGHT_DRAIN_OV
33
hard
There is excessive current in the
transport motor drive circuit
The machine is disabled
Brush motor current over
software limit
BRUSH_SOFTWARE_OV
34
soft
The brush motor current has
exceed the software limit
Brush, deck actuator and
water/suds are disabled
Brush motor current over
hardware limit
BRUSH_HARDWARE_OV
35
soft
The brush motor current has ex-
ceed the absolute hardware limit
Brush, deck actuator and
water/suds are disabled
Open circuit detected in
brush motor
BRUSH_OPEN_CIRCUIT
36
soft
An electrically open condition
has been detected in the brush
motor circuit
Brush, deck actuator and
water/suds are disabled
REGEN_CURRENT_EXCEEDED
37
LEFT_DRAIN_FAULT
38
RIGHT_DRAIN_FAULT
39
Transport motor current
over hardware limit
LEFT_SOFTWARE_OV
40
hard
The transport motor current has
exceed the absolute hardware
limit
The machine is disabled
Transport motor current
over hardware limit
RIGHT_SOFTWARE_OV
41
hard
The transport motor current has
exceed the absolute hardware
limit
The machine is disabled
BRUSH_DRAIN_FAULT
42
12VDC power supply
outside acceptable limits
SUPPLY_OUT_OF_RANGE
43
hard
The 12VDC supply voltage is less
tha 11.75V or greater than 12.25
volts
The machine is disabled
check batteries
VALVE_OPEN_CIRCUIT
44
Deck actuator motor cur-
rent over software limit
BRU_DECK_SOFTWARE_OV
45
soft
The deck actuator current has
exceed the software limit
Brush, deck actuator and
water/suds are disabled
Vacuum motor current
over hardware limit
VACUUM_HARDWARE_OV
46
soft
The vacuum motor current has
exceed the software limit
The vacuum motor is
disabled
Deck actuator motor
current over hardware
limit
BRU_DECK_HARDWARE_OV
47
soft
The deck actuator current has
exceed the absolute hardware
limit
Brush, deck actuator and
water/suds are disabled
Squeegee motor current
over software limit
SQUEE_SOFTWARE_OV
48
soft
The squeegee motor current has
exceed the software limit
The squeegee actuator is
disabled
TOUCH SCREEN ERROR CODES
Содержание GTR
Страница 15: ...FC RIDERS V2 OP EN v22 235 15 1 2 3 EMERGENCY STOP STEERING COL CONTROLS 2 3 1 ...
Страница 17: ...FC RIDERS V2 OP EN v22 235 17 25 SPRAY JET CONTROLS OPTIONAL 24 ...
Страница 22: ... 22 FC RIDERS V2 OP EN v22 235 SIDE BROOM SYSTEM OPTIONAL ON ON OFF OFF ...
Страница 25: ...FC RIDERS V2 OP EN v22 235 25 REMOVE SQUEEGEE 3 4 A B B C 1 2 2 1 ...
Страница 26: ... 26 FC RIDERS V2 OP EN v22 235 ADJUST SIDE SQUEEGEE 5 5 ...
Страница 27: ...FC RIDERS V2 OP EN v22 235 27 ADJUST SQUEEGEE 1 2 2 1 RH LH 5 16 5 16 9 16 9 16 9 16 1 2 1 2 ...
Страница 28: ... 28 FC RIDERS V2 OP EN v22 235 TRANSPORTATION FORWARD 2 ON 1 0 3 3mph 0 5 3 kph ...
Страница 29: ...FC RIDERS V2 OP EN v22 235 29 TRANSPORTATION REVERSE ON 1 2 0 1 6mph 0 2 6 kph ...
Страница 34: ... 34 FC RIDERS V2 OP EN v22 235 FLUSHING RECOVERY TANK 1 2 2 ...
Страница 35: ...FC RIDERS V2 OP EN v22 235 35 CLEAN DRAIN SAVER VAC SYSTEM 2 3 1 ...
Страница 36: ... 36 FC RIDERS V2 OP EN v22 235 CLEAN CYLINDRICAL HOPPER 2 3 4 1 ...
Страница 48: ...BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 49: ...BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Страница 50: ... RPS Corporation 2022 1711 South Street Racine WI 53404 www tomcatequip com 262 681 4060 ...