11.
User Manual | HAZECASE 1500 by Factor Fogger | July 2022
english
DMX 512 CONNECTION
CHANNEL
FUNCTION
DMX VALUE
CH 1
Control speed of fan
0~255 from small to large
CH 2
Control qty of fluid
0~255 from small to large
DMX - PROTOCOL
The wires must not come into contact with each other, otherwise the fixture will not work at all or properly. Please
note the starting address depends upon which controller is being used. Only use a DMX cable and 3 or 5 pin XLR-
plugs and connectors in order to connect the controller with the fixture or one fixture to another
Occupation of the XLR-connection
DMX output
DMX input
XLR mounting socket
XLR mounting plug
1: Ground 2: Signal (-1) 3: Signal (+) 4: Not connect 5: Not connect
1
2
3
1
5
3 2
4
1
2
3
1
5
3 2
4
CONNECTION WITH THE MAINS
The occupation of the connection cables is as follows
CABLE
PIN
INTERNATIONAL
Brown
Live
L
Blue
Neutral
N
Yellow / Green
Earth