background image

IMPORTANT NOTE:

 THIS OWNER'S MANUAL IS PROVIDED AS AN 

INSTALLATION AND OPERATING AID. FACTOR ELECTRONICS DOES NOT 

ASSUME ANY RESPONSIBILITY AS TO ITS ACCURACY AND SHALL NOT BE 

LIABLE IN TORT OR CONTRACT FOR ANY DIRECT, CONSEQUENTIAL OR 

INCIDENTAL LOSS OR DAMAGE ARISING FROM THE INSTALLATION, USE OR 

INABILITY TO USE THIS PRODUCT.

WARNING: 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT 

EXPOSE THIS APPLIANCE TO WATER, RAIN OR MOISTURE. THIS APPLIANCE 

SHOULD NOT DAMPENED BY WATER DROPS OR SPLASHING. CONTAINERS OF 

LIQUID SUCH AS VASES SHOULD NOT BE PLACED ON THIS APPLIANCE.

Immediately upon receipt, inspect the unit and shipping container for indications of improper 

handling or in-transit damage. This equipment was carefully inspected and tested before 

leaving the factory. Notify the Transportation Company, Wholesaler or Retailer immediately if 

any damage is found. Be sure to save the carton and packing material as evidence of damage 

for later inspection. DO NOT SHIP the unit back to the factory unless authorized to do so by the 

factory. IN TRANSIT DAMAGES ARE NOT COVERED BY THE WARRANTY.  

DO NOT INSTALL OR 

ATTEMPT TO OPERATE THIS UNIT IF IT HAS BEEN DAMAGED. 

IMPORTANT SAFETY INSTRUCTIONS

• Read and keep these instructions.

• Heed all warnings and follow all instructions contained within this manual.
• Do not use this unit near water.

• Clean only with dry cloth.

• Do not block any ventilation openings. Install in accordance with the manufacturer’s 

instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves, or other 

apparatus (including 

amplifiers) that produce heat.

• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug 

has two blades 

with one wider than the other. A grounding type plug has two blades and a third 

grounding prong. The wide blade or the third prong are provided for your safety. If the provided 

plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

• Protect the power cord from being walked on or pinched particularly at plugs, convenience 
receptacles, and 

the point where they exit from the apparatus.

• Only use attachments/accessories specified by the manufacturer.

• Unplug this apparatus during lightning storms or when unused for long periods of time.

• Refer all servicing to qualified service personnel. Servicing is required when the apparatus 
has been 

damaged in any way, such as when the power-supply cord or plug is damaged, liquid 

has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to 

rain or moisture, does not operate normally, or has been dropped.

• Operate the product only with the voltage specified on the unit. Fire and/or electric shock 

may result if a 

higher voltage is used.

• Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to 

heaters and 

do not place heavy objects on the power cord and/or the product itself, doing so 

may result in fire or electrical shock.

• Replace the protective cover over the speaker terminals after installation. Do not touch the 
70V speaker 

terminals as electric shock may result.

• Ensure that the safety ground terminal is connected to a proper ground. Never connect the 

ground to a gas 

pipe, as a severe explosion and/or fire may result.

• Be sure the installation of this product is stable, avoid slanted surfaces as the product may 
fall and cause 

injury, property damage, electrocution and/or fire.

• Note when the unit is turned off it is not completely disconnected from the wall AC power 

outlet. Do not open 

the cover unless the device is unplugged from the wall AC power outlet.

[email protected]

       www.factorelectronics.com

2

2

Содержание COMM-2

Страница 1: ...sonal Information Before using this product you should ensure that you are in compliance with any applicable law This may include ensuring you have obtained any required express or implied consent for the collection of personal information In using this product you take full responsibility for its proper use Factor Electronics authorized Factor Electronics distributors and re sellers are not respo...

Страница 2: ... A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use...

Страница 3: ...and microphone in a weather resistant enclosure NOTE the COMM 2 should be installed by a qualified installation professional Unpacking The COMM 2 includes the following parts 1 x COMM 2 amplified horn speaker microphone 1 x Integrated swivel mount 2 x 3 5mm 3 5mm connection cables heat shrink tubing to seal the connections 1 x Product Manual Optional COMM 2 PWR SUP Quick Start To get up and runnin...

Страница 4: ...COMM 2 with the input level of the camera system NOTE the COMM 2 ships with the audio output level set to low level approx 165mV unbalanced or 450mV balanced The audio output level can be changed by opening the back panel amplifier cover and setting the slide switch The high level audio output is approx 450mV Unbalanced and approx 1V balanced See the diagram below 4 The COMM 2 horn speaker output ...

Страница 5: ...with balanced connections 2 The COMM 2 includes 2 x shielded unbalanced 3 5mm male to male 6 cables and 2 x balanced 3 5mm female input output connectors wired as follows 3 NOTE using an unbalanced connection at one end of the cable and a balanced connection at the other end of the cable will result in the entire connection being unbalanced To maintain a low noise connection use a balanced connect...

Страница 6: ... being added to an existing audio system in a large building and used for two way communications without an IP camera A single COMM 2 can provide both talk and listen audio functions Factor Desk Mic Factor SPA 12 pre amp Factor Comm 2 XLR Cable 300 XLR F 3 5 Cable 300 To COMM 2 audio in Balanced wiring setup for talk paging Balanced wiring setup for listening Factor C 855R speaker Factor X 530 Amp...

Страница 7: ...ee mounting screws bolts must be used 3 Re attach the horn to the mount with the Mounting Bolt and tighten the mounting bolt securely 4 Loosen the Angle adjustment wing nut to approx 75 but do not remove the wing nut Push the wing nut to release the wing bolt Now the COMM 2 will rotate Rotate to the desired angle and tighten the Angle adjustment wing nut 5 Connect the cables and test the COMM 2 6 ...

Страница 8: ... peak Max SPL 122dB Amplifier class D THD 1 amplifier THD 5 speaker amplifier Input sensitivity 3 5mm balanced 160mV full power Input sensitivity 3 5mm unbalanced 300mV full power Output level 3 5mm balanced 1V Output impedance balanced 1200ohms Output level 3 5mm unbalanced 450mV Output impedance unbalanced 600ohms Talk Listen relay threshold 35mV 5mV Speaker type Re entrant Horn Operating temper...