FACTO 87795007 Скачать руководство пользователя страница 4

!

CAUTION

When the air filter is to be 
removed, do not touch the 
metal parts of the unit.

It may cause an injury.

Do not clean unit when 
power is on as it may cause 
fire and electric shock, it may
cause an injury.

Operation with windows 
opened may cause wetting
of indoor and soaking of 
household furniture.

When the unit is to be 
cleaned, switch off, and turn
off the circuit breaker.

Stop operation and close 
the window in storm or 
hurricane.

Use caution when unpacking and 
installing. Sharp edges could cause injury.

Do not clean the air 
conditioner with water.

Water may enter the unit and 
degrade the insulation. It may 
cause an electric shock.

This could injure the pet or
plant.

and damage.

Do not put a pet or house 
plant where it will be
exposed to direct air flow.

Hold the plug by the head 
of the power plug when 
taking it out.

Ventilate the room well when
used together with a stove, 
etc.

An oxygen shortage may occur.

Do not use this air conditioner to 

preserve precision devices, food,

pets, plants, and art objects.

It may cause deterioration of 

quality, etc. 

It may cause failure of product 

or fire.

Do not use for special 
purposes.

Turn off the main power  
switch when not using the
unit for a long time.

If water enters the unit, turn the unit off at the power 

outlet and switch off the circuit breaker. Isolate 

supply by taking the power-plug out and contact a 

qualified service technician.

!

!

!

!

!

!

!

It may cause failure of 
appliance or accident.

Appearance may be 
deteriorated due to change
of product color or 
scratching of its surface.

Do not place obstacles 
around air-inlets or inside 
of air-outlet.

Do not use strong deter-
gent such as wax or 
thinner but use a soft cloth.

If bracket is damaged, there
is concern of damage due to
falling of unit.

There is danger of fire or 
electric shock.

Ensure that the installation bracket of 
the outdoor appliance is not damaged 
due to prolonged exposure.

Do not place heavy object on the 
power cord and ensure that the cord
is not compressed.

Operation without filters may

cause failure.

It contains contaminants and 

could make you sick.

Always insert the filters 
securely. Clean filter once 
every two weeks.

Do not drink water drained 
from air conditioner.

!

!

!

 3

Содержание 87795007

Страница 1: ...WINDOW AIR CONDITIONER OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS 87795007 MWK 08CMN1 BJ8 ...

Страница 2: ...unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work shall be performed by authorized personnel only Installation work must be performed in accordance...

Страница 3: ...r fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may cause fire and electric shock It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufac turer or an authorized service centre or a similarly qualified per son in order to avoid a hazard This could damage yo...

Страница 4: ...lants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician It may c...

Страница 5: ...NOTE The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event that the power supply cord is damaged it cannot be repaired it must be replaced with a cord from the Product Manufacturer Do not under any circumstances cut remove or bypass the grounding prong ...

Страница 6: ... 0 5 6 7 889 5 9 6 8 8 FG K 8 L N 8 8 N 0QX 㨫 N 0ZX 㨫 Q Q 5L F 0 F6 5L7 F QL F6 _ 5 ...

Страница 7: ...e left to select your choice of fan speeds for air circulation NOTE When selecting a fan speed the compressor will not run On models with a vent control this mode can be used to remove stale air from the room or to draw fresh air into the room Check the section Additional Things You Should Know Thermostat The thermostat is used to set the desired room temperature when the unit is being operated in...

Страница 8: ...l will maintain any set temperature within 1 F 1 C between 62 F 17 C and 86 F 30 C The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Temp Timer buttons at the same time for 3 seconds Air Directional Louvers The louvers will allow you to direct the air flow Up or Down and Left or Right through...

Страница 9: ...1 Mounting Hardware TOOLS NEEDED Phillips Screwdriver Drill If pilot holes are needed CAUTION When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils Top Rail Hardware 3 8 Screws 4 Top Rail 1 Before installing unit the top rail must be assembled on the unit Tool Needed Phillips Screwdriver A Remove the air conditioner from the carton and place o...

Страница 10: ...Fig 1 A Hold the Accordion Panel in one hand and gently pull back the center to free the open end See Fig 1 B Slide the free and I section of the panel into the cabinet as shown in Fig 2A 2B 3 Slide the panel down Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet C Once the panel has been installed on the side of the cabinet make sure it sits secur...

Страница 11: ...e window behind the top rail of the unit 2 Extend the side panels out against the window frame Fig 6 3 Place the frame lock between the frame exten sions and the window sill as shown Fig 7 Drive 3 4 19mm locking screws through the frame lock and into the sill Fig 8 NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws 4 Fig 7 Fig 8 Fig 5 Fig 6 10 ...

Страница 12: ...Rain Water or Condensation must be allowed to drain out Storm window frame or other obstruction 11 2 MIN 38 mm Sash Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Fig 13 Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety lock Remove screws installed through frame and frame lock C...

Страница 13: ... the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly...

Страница 14: ...ature to a lower setting Air directional louvers positioned improperly Position louvers for better air distribution Front of units is blocked by drapes blinds furniture etc restricts air distribution Clear blockage in front of unit Doors windows registers etc Open cold air escapes Close doors windows registers Compressor shut off by changing modes Wait approximately 3 minutes and listen for compre...

Страница 15: ...uestions please contact our toll free service line at 1 866 206 0888 from 8 AM to 6 PM Monday to Friday Eastern time The product is guaranteed for 36 months if used for normal trade purposes and is valid for the original buyer only Any warranty is deemed invalid if the product has been overloaded or used improperly or subject to neglect attempted repair other than by an authorized agent Heavy duty...